3P Technik 1000650 Petunjuk Pengoperasian - Halaman 2

Jelajahi secara online atau unduh pdf Petunjuk Pengoperasian untuk Sistem Penyaringan Air 3P Technik 1000650. 3P Technik 1000650 4 halaman. Rainwater filter for bigger roof areas

Operating and assembly instructions
Twin Filter
The 3P Twin filter can be installed in an underground chamber or outside in frost-free regions
directly on the wall. The filter can be delivered to the construction site in the shaft in pre-assem-
bled condition. Due to its 2-stage cleaning principle, it has a high degree of efficiency indepen-
dently of the volume of flow. The filtered-out dirt is continuously flushed towards the sewerage
system due to the steep inclination of the filter inserts. The clean water is collected in a sump
and directed to the reservoir.
How it works:
1. Incoming rainwater is collected in the sump and
evenly directed on both sides via the cascades =
weir over principle.
2. Pre-cleaning according to the cascade principle.
Coarse dirt is directed straight to the sewerage system
via the cascades.
3. Pre-cleaned water is guided to the filter mesh screens
(mesh width 0.65 mm). The filtered-out dirt is flushed into
the sewerage system via the bottom connections due to
the special owen mesh structure and the steep inclination of the mesh.
4. The cleaned water is collected in the central sump and directed
to the rainwater storage tank via one or both connections.
5. The filtered-out dirt is flushed into the sewerage system
via the shaft or pipe outlet.
Connections:
Rainwater supply 2 x DN 100 / DN 150
Rainwater reservoir supply 2 x DN 100 / DN 150
Dirty water connection
2 x DN 100 / DN 150
Sole, supply Sole, drain into reservoir
Sole, supply Sole, drain intosewerage system
2
3
f h
Difference Alignment
350 mm
directly underneathone another
510 mm
offset by 160 mm
1
4
h
160 mm
Rainwater supply
Rainwater reservoir
connection
Dirty water / channel connection
680 mm
5