3rd Power DREAM 50 PLEXI MKII Panduan Pengguna - Halaman 12

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Penguat Alat Musik 3rd Power DREAM 50 PLEXI MKII. 3rd Power DREAM 50 PLEXI MKII 15 halaman. Guitar amplifier

3rd Power DREAM 50 PLEXI MKII Panduan Pengguna

Operational Notes:

TUBE CHART
V2
V1
V5
V4
V6
preamp
preamp
output
output
output
phase inverter
Tube Layout and Requirements:
V1 and V2: JJ 12AX7 (Preamp)
V3: Sovtek 12AX7LPS (Phase Inverter)
V4 and V5: EL34 or 6L6GC output tubes
V6: Rectifier tube socket
• Model Dream 40 American and Dream 40 AC loaded with GZ34 Tube Rectifier
• Model Dream 50 Plexi loaded with Diode Rectifier Adapter

Bias Adjustment

Your Dream Amp comes from the factory biased for EL34 or 6L6GC tubes. Bias adjustments are not
intended to be user-serviceable. Attempting to adjust the bias yourself will expose you to very dan-
gerous high-voltage electricity that can kill you. Special test equipment and knowledge of amp cir-
cuits and tubes are required to perform this function. DO NOT ATTEMPT TO DO THIS YOURSELF.

Tube Replacement

WE RECOMMEND TAKING YOUR AMPLIFIER TO A QUALIFIED TECHNICIAN FOR SERVICING YOUR
TUBES. Make certain the amplifier is turned off and has been allowed ample time to cool down. Be
very careful when you remove the tubes as they might still be very hot! Do not touch tube sockets
with fingers! Even after turning your amp off and unplugging it from the power outlet there could be
enough voltage stored in the capacitors to give you a lethal electrical shock.
WARNING:
• Do not remove the back panel.
• Do not attempt to check or replace tubes yourself. Refer to an authorized service center.
• Never touch the tubes while the amplifier is turned on or has recently been turned ON. You can
severely burn your fingers and hands.
12