Danfoss VLT HVAC Drive FC 102 Buku Petunjuk - Halaman 7

Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Pengontrol Danfoss VLT HVAC Drive FC 102. Danfoss VLT HVAC Drive FC 102 16 halaman. Igbt module replacement for d1h–d8h drives
Juga untuk Danfoss VLT HVAC Drive FC 102: Panduan Pengoperasian (16 halaman), Panduan Instalasi (20 halaman), Panduan Petunjuk Instalasi (6 halaman), Panduan Petunjuk Instalasi (12 halaman), Panduan Instalasi (18 halaman), Panduan Petunjuk Instalasi (11 halaman), Panduan Petunjuk Instalasi (8 halaman), Panduan Petunjuk Instalasi (10 halaman), Panduan Instalasi (6 halaman), Panduan Petunjuk Pengoperasian (16 halaman), Panduan Petunjuk Instalasi (6 halaman), Panduan Instalasi (16 halaman), Panduan Instalasi (8 halaman), Panduan Petunjuk Instalasi (6 halaman), Panduan Instalasi (6 halaman)

Danfoss VLT HVAC Drive FC 102 Buku Petunjuk

Safety

2 Safety

2.1 Safety Symbols

The following symbols are used in this document:
WARNING
Indicates a potentially hazardous situation that could
result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation that could
result in minor or moderate injury. It can also be used to
alert against unsafe practices.
NOTICE!
Indicates important information, including situations that
can result in damage to equipment or property.

2.2 Qualified Personnel

The products may only be assembled, installed,
programmed, commissioned, maintained, and decommis-
sioned by persons with proven skills. Persons with proven
skills
are qualified electrical engineers, or persons who
have received training from qualified electrical
engineers and are suitably experienced to
operate devices, systems, plant and machinery in
accordance with the general standards and
guidelines for safety technology.
are familiar with the basic regulations concerning
health and safety/accident prevention.
have read and understood the safety guidelines
given in this manual and also the instructions
given in the Instruction Manual of the adjustable
frequency drive.
have a good knowledge of the generic and
specialist standards applicable to the specific
application.
Users of PDS(SR)s are responsible for:
Hazard and risk analysis of the application.
Identifying safety functions required and
allocating SIL or PLr to each of the functions.
Other subsystems and the validity of signals and
commands from them.
MG37D222
Instruction Manual
Protective measures

2.3 Safety Precautions

See the Safety chapter in the relevant Instruction Manual
for general safety precautions.
CAUTION
After installation of STO, perform a commissioning test
as specified in chapter 4.5 STO Commissioning Test. A
passed commissioning test is mandatory after first instal-
lation and after each change to the safety installation.
WARNING
RISK OF DEATH AND SERIOUS INJURY
If external forces act on the motor, e.g., in the case of
vertical axis (suspended loads) - and an unwanted
movement, e.g., caused by gravity, could cause a hazard,
the motor must be equipped with additional measures
for fall protection. For example, mechanical brakes must
be installed additionally.
WARNING
RISK OF DEATH AND SERIOUS INJURY
STO (i.e., removal of 24 V DC voltage supply to terminal
37) does not provide electrical safety. The STO function
itself is not sufficient to implement the Emergency Off
function as defined by EN 60204-1. Emergency Off
requires measures of electrical isolation, e.g., by
switching off line power via an additional contactor.
Danfoss A/S © 09/2014 All rights reserved.
Designing appropriate safety-related control
systems (hardware, software, parameterization,
etc.).
Safety engineering systems may only be installed
and commissioned by qualified and skilled
personnel.
Install the adjustable frequency drive in an IP54
cabinet as per IEC 60529 or in an equivalent
environment. In special applications, a higher IP
degree may be necessary.
Ensure short circuit protection of the cable
between terminal 37 and the external safety
device according to ISO 13849-2 table D.4.
When external forces influence the motor axis
(e.g., suspended loads), additional measures (e.g.,
a safety holding brake) are required to eliminate
hazards.
2
2
5