Dunavox DAU-17.57DB Buku Petunjuk - Halaman 12

Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Pendingin Anggur Dunavox DAU-17.57DB. Dunavox DAU-17.57DB 16 halaman.
Juga untuk Dunavox DAU-17.57DB: Buku Petunjuk (20 halaman)

Dunavox DAU-17.57DB Buku Petunjuk
This will create a continuous climate in the cabinet
which imitates that of a wine cellar.
In the Dynamic Climate mode, the interior fan
circulates the inside air even if the set temperature is
reached. Dynamic Climate mode is NOT the factory
preset mode because of creating noises and more
energy consumption. To change to Dynamic Climate
mode,
touch and
hold the DOWN
approximately five seconds.
beep five times to confirm Dynamic Climate mode is
on. To change back to default (Silent) mode (Also
named as energy saving mode), touch and hold the
UP key for approximately five seconds. The wine
cellar will beep three times to confirm default (Silent)
mode is on.

SABBATH MODE

Sabbath mode is available for the observance of
certain religious holidays. This mode turns off the
displays, interior light and audible alarms and
prevents them from turning on again. Normal cooling
operations will still take place.
To initiate Sabbath mode, press the POWER and
LIGHT keys at the same time for at least 5 seconds.
The indicator light will flash four times and confirm
the Sabbath mode is ON.
Sabbath mode can be exited by repeating the above
process. The Sabbath Mode will automatically exit
after 96 hours.
ECO DEMO MODE
Eco Demo mode can be activated by presenting the
appliance at exhibitions or in salesrooms. In Eco
Demo mode, the compressor and all fan motors are
switched OFF.
By pressing and holding the "UP"&"DOWN" (The
controls of lower zone for dual zone & three zone
models) and "LIGHT" keys at the same time for at
least 5 seconds, the indicator light will flash five
times to confirm the input and the unit will operate in
Eco Demo mode. Eco Demo mode can be exited by
repeating the above process.

GENERAL INFORMATION

Operating Noises

The unit is cooled by a compressor (refrigeration
aggregate). The compressor pumps coolant through
the cooling system, producing operating noise. Even
when the compressor cuts out, noises caused by
changes
in
temperature
unavoidable. Operating noise will be most audible
immediately after the compressor cuts in. It
becomes quieter as the operating period continues.
The following noises are normal and occur from time
to time:
- Gurgling sound, caused by the refrigerant flowing
key for
The wine cellar will
and
pressure
are
through the appliance's coils,
- Humming noise made by the motor compressor.
This noise can get louder for brief periods when
the motor is switching on.
- Cracking/popping sounds, resulting from the
materials contraction and expansion due to
temperature variations,
- Fan operating sound, to circulate the air within the
wine cabinet.
Unusual noise is normally the result of improper
installation. Under no circumstances must tubing
come into contact with a wall, other furniture or with
other tubing.
Where the unit is installed in open-plan kitchen or in
partition walls, the level of operating noise will be
heard more acutely. However, this is due to the
surrounding architecture and not to the unit.
An individual's perception of noise is directly linked
to the environment in which the unit is located, as
well the specific type of models. Our appliances are
in line with international standards for such
appliance and in line with the latest technical
developments. But please remember that the noise
of the compressor and the coolant circulating in the
system is unavoidable.
DEFROSTING / HYGROMETRY /
VENTILATION
Your unit is designed with an automatic defrost
system. During the "Off-cycle" the evaporator behind
the rear wall of the unit defrosts automatically. The
condensate collects in the drain trough behind the
rear wall of the unit, and part of it flows through the
drainage hole into the drip tray by/above the
compressor. The heat is transferred from the
discharge pipe or compressor and evaporates any
condensation that has collected in the tray. Part of
the remaining water is collected within the unit for
humidity purposes.
This system enables the creation of the correct
humidity level inside your unit required by the natural
cork to maintain a long lasting seal.
The appliance is not totally sealed: fresh air
admission is permitted through the drainpipe. Air is
circulated through the unit by means of a fan / fans
and the hollow shelves.
NOTE: Frost may be accumulated on the evaporator
if the unit is repeatedly opened in a high heat or high
humidity location. If this frost pattern does not clear
within 24 hours, your unit will require manual
defrosting.

CARE AND MAINTENANCE

WARNING: Failure to unplug the appliance during
service and cleaning could result in electrical shock
or other personal injury.
12