Aolait ALED BSW CMY 400 Panduan Pengguna - Halaman 18

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Perlengkapan Lampu Aolait ALED BSW CMY 400. Aolait ALED BSW CMY 400 20 halaman.

product, and the leakage protector, overcurrent protector, etc. meet the requirements of the
load;
Do not use power cords with damaged insulation, and do not overlap power cords with
other wires;
The lamp adopts strong air cooling, which is easy to accumulate dust. It must be cleaned
once a month, especially the heat dissipation vent, otherwise it will be blocked by the
accumulation of dust, resulting in poor heat dissipation and abnormalities in the lamp.
When installing the lamp, the fixing screws must be fastened, with safety cables, and regular
inspections;
When installing and positioning the luminaire, keep a minimum distance of 10 meters
between any point on the surface of the luminaire and any flammable and explosive object,
and the distance from the irradiated object is 2.5 meters. Please do not install the luminaire
directly on the surface of combustible materials.;
It is recommended that the continuous working time of the lamp should not exceed 10
hours, and the interval between continuous starting of the lamp should not be less than 10
minutes, otherwise it will not be triggered normally due to the lamp overheating
protection;
The closing time using the on-off valve should not exceed 5 minutes. If you need to close the
light for a long time, you should use the console (lighting control channel) to turn off the
light.;
In order to ensure that multiple luminaires better comply with the scene effect, the
luminaire should not be in the unfinished current scene all the time, that is, start the next
scene action, it is best not to exceed 3 minutes in this state to ensure that multiple
luminaires can run simultaneously;
During use, if there is an abnormality in the lamp, stop using the lamp in time to prevent
other malfunctions.
3. Precautions for using RDM
RDM is an extended version of the DMX512-A protocol. It is a remote device management
protocol. The traditional DMX512 protocol communication is one-way communication. The
protocol is based on the RS-485 bus. RS-485 is a time-sharing multi-point, half-duplex protocol.
Only allowed at the same time One port is the output of the host, so, pay attention to the
following points when using RDM:
To use a console or host device that supports the RDM protocol host;
To use a two-way signal amplifier, the traditional one-way signal amplifier is not suitable for
the RDM protocol, because the RMD protocol requires feedback data, and the use of a
one-way amplifier will block the returned data, resulting in the search for lamps and
lanterns;
All lamps must be set to DMX mode to ensure that there is only one host on the signal line;
A 120ohm impedance matching resistor must be inserted between terminals 2 and 3 of the
terminal plug. When the signal line is relatively long, the use of differential signals will be
more stable when the signal line is relatively long, which is conducive to the quality of
communication;
When it appears that the lamp accepts DMX control, but cannot search for the lamp by RDM, first
check the signal amplifier, and then check whether there is a bad connection between the 2 and
3 lines of the signal line.