BUILT-UNDER INSTRUCTIONS
Make sure your installation does not block the front
ventilation grille. The unit is designed to fit under
worktops between 820 and 890mm in height. Remove
the adjustable ventilation grille screws and slide it to
the required height. Tighten the screws to lock the
grille in position.
If the unit is fully integrated to be installed for fitting
kitchen plinth, make sure that the ventilation gaps in
the plinth are at least 300 square centimeters and
remove the ventilation grilles, so that warm air can
disperse unhindered. Otherwise the appliance has to
work harder, resulting in an increase in electricity
consumption.
NOTE: When pushing the appliance into the niche,
make sure that the mains cable does not get trapped.
FULLY INTEGRATED BUILT-IN-COLUMN
INSTRUCTIONS
The unit door seals the installed unit almost
completely, so an air vent must be provided in the
base of the housing. Warmed air must be conducted
via the ventilation shaft to the rear wall of the housing
and then expelled upwards. The ventilation channels
should measure at least 200 square centimeters in
cross-section.
WARNING: To ensure the proper functioning of the
appliance, air vents should never be blocked or
covered.
BUILT-IN CABINET INSTRUCTIONS
Make sure your installation does not block the front
ventilation grille. And be sure the door will open and
close properly in the chosen location.
YOU CAN FIND THE DETAILED
INSTALLATION DRAWING IN THE
ATTACHMENT
ELECTRICAL CONNECTION
WARNING:
Improper use of the grounded plug can
result in the risk of electrical shock. If the power cord
is damaged, have it replaced by a qualified electrician
or an authorized service center.
All electrical work should be carried out by a suitably
qualified and competent person in accordance with
local and national safety regulations.
Check that the voltage marked on the product
corresponds with your supply voltage.
Connect this appliance to a separate, at least 13A
circuit.
Connection should be made via a suitable switched
socket which is easily accessible. For extra safety it is
advisable to install a residual current device (RCD)
with a trip current of 30mA.
Have the receptacle and the circuit checked by a
qualified electrician to ensure that the socket is
grounded correctly.
Note: In locations where there is frequent lightning,
it is advisable to use surge protectors.
Do not connect the appliance to the mains electricity
supply by an extension lead. Extension leads do not
guarantee the required safety of the appliance (e.g.
danger of overheating).
The appliance must not be connected to an inverter
and must not be used with a plug adapter as these
can cause damage to the appliance's electronic unit.
The cord must rest securely behind the appliance and
not be allowed to lie or hang unprotected.
WARNING:
THIS APPLIANCE MUST BE EARTHED.
INSTALLING THE HANDLE
IMPORTANT: Do not overtighten the screws & do not
use power tools to install the handle. Overtighten
screw causes glass breakage.
DESIGN 1 –
Locate the handle ①,over the fixing pins ③,of the
door and using the supplied allen key, tighten the
securing grub screws ②,to fix the handle.