Danfoss HP8321-1RJ Panduan Petunjuk Instalasi - Halaman 2
Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Termostat Danfoss HP8321-1RJ. Danfoss HP8321-1RJ 8 halaman. Heat pump thermostats
Setting the DIP Switches
Switch Location
How to disable the reset button
To prevent unauthorised resetting of programs and advanced programing options the reset button can be disabled.
How to Lock the Front Cover
If locking is required fit locking piece before fitting the
thermostat to wallplate. Do not close the front cover
until the thermostat has been fitted to the wallplate.
To open a locked cover, slide a flat-blade screwdriver
in from the side between the bottom of the thermo-
stat and center locking tab. Gently twist the blade to
pry open the cover.
Attaching the Thermostat onto the
Wallplate
(see illustrations to right)
To remove the thermostat from the wallplate, open
the front cover, place a flat blade screw driver into
the slots on top of the thermostat and gently twist.
Once both slots are done, gently pull top of thermo-
stat towards you. Note: do not press down on the
white tabs as this could damage the thermostat.
Wiring Access
1. Removing the thermostat
terminal cover
2
➔ ➔ ➔ ➔ ➔
Switch
= On
= Off
Non-prog =
1 Off & 2 On
2 Events =
1 Off & 2 Off
*
4 Events =
1 On & 2 Off
6 Events =
1 On & 2 On
7 Day
=
3 On & 4 Off
*
5/2 Day =
3 Off & 4 Off
24hr
=
3 On & 4 On
Disable = 5 On
Keyboard
Enable = 5 Off
*
Changeover Auto =
6 Off
*
Man =
6 On
Electric = 7 Off
*
Aux Heat
Fossil =
7 On
Occ Relay N/O =
8 Off
N/C =
8 On
*
Enabled On
Disabled Off
2. Correct wiring access
a)
Feed the wires
through the access in
the rear of the
wallplate.
b)
Wires must enter
from below the
terminal block
screws
A) It is advisable to make DIP switch settings prior
to installing the thermostat on the wallplate.
B) If Keyboard Disable function is required (DIP
switch 5), do not set until any advanced
programming options are completed, and user
programs have been set.
C) To return the thermostat DIP switches to the
factory setting set switches as indicated by
▲
ON
= reset enabled
*
▲
ON
= reset disabled