Danfoss TP5000 RF Si Panduan Instalasi dan Petunjuk Pengguna
2) Chrono-Proportional - energy saving feature which fi res
the boiler at regular intervals to maintain a set temperature,
achieving a constant ambient environment for the user.
For a full explanation of all advanced features please
visit our website www.danfoss-randall.co.uk or call 01234
364621 to obtain a copy of our Advanced Features Guide.
Thermostat Wiring (not RF models)
!
Some existing thermostats will have a Neutral and/or Earth wire connected.
These are not required by the TP5000 and must NOT be connected to any
TP5000 terminals. Instead they should be made electrically safe and coiled
in the recess at the back of the TP5000.

RX Receiver Wiring (RF models only)

RX1 & RX2
NB. For mains voltage operated systems link terminal 2 to mains live supply
COM
RX3
5