Instruction
4.
Disassembling and
assembling of the
swash plate
12
Disassembling and assembling APP 11-13 and APP 16-22
WARNING:
Make sure that the surface on the swash plate
does not get any marks.
1.
Place the swash plate upside down.
Remove the 2 bolts holding the swash
plate.
Remove the mounting flange from the
swash plate.
3.
Change the O-ring on the mounting flange.
5.
Mount the assembled part on the pump.
(Remember to lubricate the O-ring).
180R9228 / 521B1181 / DKCFN.PI.013.A2.02 / 10.2013
2.
Change the O-rings and guide pins.
(Provided with sealing set).
O-rings
4.
Mount the swash plate on the 2 guide pins.
Carefully by hand tilt the unit horizontally
and mount the 2 bolts which hold the
swash plate. Tighten the bolts with a
torque of 30 Nm +/-2 Nm.
Finally check the surface on the swash plate
for any marks or foreign particles.