Disassembling and Assembling, APP 1.5-3.5
Service guide |

Table of Contents

Introduction

2 | 180R9091 | DKCFN.PI.013.EF5.02 | 521B0741
Contents
Introduction ................................................................................................................................................................................2
1.
Disassembling and assembling the pump .............................................................................................................3
2.
Change of shaft seal .......................................................................................................................................................7
3.
Exploded views.............................................................................................................................................................. 10
3.1 APP 1.5-2.5 ...................................................................................................................................................................... 10
3.2 APP 3.0-3.5 ...................................................................................................................................................................... 11
NOTE: If the pump is disassembled within the warranty period, the pump is no longer covered
by the warranty.
This document covers the instructions for
disassembling and assembling the axial piston
pump APP 1.5-3.5
Important: It is essential that the pump is
serviced in conditions of absolute cleanliness.
To understand the pump design better, please
see exploded view on last page.
Tools needed:
Shaft seal tool (code no. 180B4148)
Press bush
Allen key 5mm
2 Screwdrivers
WARNING: Do not reuse disassembled O-ring
or shaft seal as they might be damaged.
© Danfoss | DCS (im) | 2017.08