Danfoss APP 38/1500 Panduan Servis - Halaman 13

Jelajahi secara online atau unduh pdf Panduan Servis untuk Pompa Air Danfoss APP 38/1500. Danfoss APP 38/1500 20 halaman. Disassembling and assembling

Service guide | Disassembling and Assembling, APP 21 - 46 and APP W HC 15 - 30
© Danfoss | 2023.03
5. If the flange does not move forward -
loosen the drain plug to empty the pump
from water by releasing vacuum.
7. Carefully turn the flange and push it
backwards to make it rest on the housing
surface. Ensure not to scratch the swash
plate surface.
9. Screw the stop for the retainer plate into
the centre to keep retainer plate/retainer
ball assembly in place.
Drain plug
6. Remove the flange when the remaining
Swash plate
surface
8. Adjust the retainer plate to be parrallel to
10. Carefully remove the pistons one by one.
three screws have been loosened. The
guide bolt must remain mounted.
the end flange.
180R9406 | AX274339308034en-000302 | 13