13. Remove spring from poppet and poppet
guide and remove O-ring from poppet
guide.
15. Turn flushing valve upside down. If not
properly assembled, spring will fall out.
17. Position the port plate over the guide pin.
IMPORTANT: Make sure that the guide
pin is located in the locating hole in the
port plate
14. Press new spring onto shoulders of
poppet guide and poppet so it is stuck
on both collars. Then mount new O-ring
on poppet guide.
16. Mount flushing valve by pressing it into
the hole.
Locating hole
Guide pin
18. Replace the O-ring on the port flange and
position the new cylinder barrel on the
port plate.
180R9091| DKCFN.PI.013.EF5.02 | 521B0741| 5
O-ring