Danfoss PAHT 256-308 Instruksi - Halaman 13
Jelajahi secara online atau unduh pdf Instruksi untuk Pompa Air Danfoss PAHT 256-308. Danfoss PAHT 256-308 20 halaman. Paht and paht g 256-308 disassembling and assembling
Instruction
Disassembling and assembling PAHT and PAHT G 256-308
5. If the flange does not move forward -
loosen the drain plug to empty the pump
from water by releasing vacuum.
7. Carefully turn the flange and push it
backwards to make it rest on the housing
surface. Ensure not to scratch the swash
plate surface.
9. Screw the stop for the retainer ring into
the centre to keep the retainer ball in
place.
180R9268 / 521B1236 / DKCFN.PI.011.B3.02 / 01.2015
Drain
plug
6. Remove the flange when the remaining
three screws have been loosened. The
guide bolt must remain mounted.
Swash plate
surface
8. Adjust the retainer plate to be parallel to
the end flange.
10. Carefully remove the pistons one by one.
13