Instruction
Disassembling and assembling PAH 10-12.5, PAHT 10-12.5 and PAHT G 10-12.5
16.
Place the screw in the center hole.
18.
Mount the pump housing using the pin as
guide.
Alignment
hole
Guide pin
20.
Tighten the screws to a torque of 22 Nm.
180R9095 / 521B0986 / DKCFN.PI.010.NA3.02 / 09.2013
17.
Tighten to a torque of 10 ±1 Nm.
19.
Press the housing down by hand and insert
the screws.
21.
Mount the two O-rings in the flange and
the O -ring on the front cover.
13