Instruction
Table of Contents
1.
Introduction
2
Disassembling and assembling PAHT and PAHT G 256-308
Contents
1.
2.
3.
4.
5.
6.
7.
8.
9.
PAHT G 256-308
This document covers the instructions for disassembling and assembling the axial piston pumps
PAHT and PAHT G 256-308.
Tools provided with toolset 180B4172:
•
10 mm combination wrench
•
13 mm combination wrench
•
6 mm allen key
•
Adjustable pin wrench
•
Stop for retainer plate
•
Press bush for valve plate
•
Shaft seal extractor Ø45
•
M8 allen screw (20 mm and 140 mm)
•
Press bush Ø45 (Plastic)
•
M8 mm eye bolt
•
M8 mm nut
•
M8 x 70 mm screw
180R9268 / 521B1236 / DKCFN.PI.011.B3.02 / 01.2015
Important: It is essential that the pump is
serviced in conditions of absolute cleanliness.
Place the pump on a pallet or other stable
surface above the ground. Ensure that the pump
cannot roll. It must be possible to place the pump
vertically with the shaft pointing downwards. This
can be done between two pallets or between
two boards on a pallet provided that the distance
is minimum 50 mm.
For a better understanding of the pump, please
see the exploded view on page 19 and 21.
WARNING:
Do not reuse disassembled O-rings or shaft
seal as they might be damaged. Always use
new O-rings.
2
3
6
10
11
12
15
17
18
18
19
19