DUO-FAST DF150-CS Manual dan Skema Pengoperasian - Halaman 5

Jelajahi secara online atau unduh pdf Manual dan Skema Pengoperasian untuk Alat Listrik DUO-FAST DF150-CS. DUO-FAST DF150-CS 16 halaman. Cap stapler

TOOL INSTALLATION
Your
tool comes ready for immediate use
Duo-Fast
®
and can be installed by following these steps:
1. SAFETY - All tool operators and their immediate
supervisors must become familiar with the operator
safety instructions before operating the tool. The
instructions are on page 4 of this manual.
2. Included with each tool is a copy of this
manual and tool schematic.
Keep this publication for future reference. An
o ownership registration card is also included.
This card must be completed and returned to
immediately to register your ownership.
Duo-Fast
®
3. The tool is shipped with a 1/4" male air fitting.
If you replace the air fitting, use only a male
pneumatic type that discharges the air from the
tool when the air line is disconnected.
4. Install a filter/regulator/lubricator unit, with a
gauge as close as practical to the tool, preferably
within ten feet. Refer to the Air Systems section of
this manual for air hose requirements and lengths.
In general, no other special installation is required.
5. If the operator is working at a bench or table,
it is usually best to run the air line underneath the
bench. A small tray under the benchtop can hold
the fastener supply and the tool when not in use.
6. If this tool does not work when it is first connect-
ed, do not try to make repairs. Call your
representative immediately.
Pneumatic System Maintenance
- Be certain that:
• Pneumatic fittings are tight and do not leak.
and ensure that automatic draining systems are
operating correctly.
• Air lines are cleared to prevent freezing,
especially in winter.
• Lubricator operation is checked regularly and
ensure it has an adequate supply of lubricant.
( Part No. 403720).
• Only regulated air is being used and that each
regulator is operating properly.
Tool Lubrication
It is most important that the tool be properly
lubricated by keeping the air line lubricator filled
and correctly adjusted. Without proper lubrica-
tion the tool will not work properly and parts will
wear prematurely.
Use the proper lubricant in the air line lubricator.
The lubricator should be of low air flow or
changing air flow type, and should be kept filled
to the correct level.
Use only
Substitutes may harm the rubber compounds in
the tools O-rings and other rubber parts. Part No.
403720 is a pneumatic lubricating oil specially
made for pneumatic applications.
Duo-Fast
®
If a filter/regulator/ lubricator is not installed on
the air system, air operated tools should be
lubricated at least once a day with 6-12 drops of
oil, depending on the work environment, directly
through the male fitting in the tool housing.
5
recommended lubricants.
Duo-Fast
®