Audiodesksysteme Gläss Vinyl Cleaner PRO Panduan Petunjuk Pengoperasian - Halaman 10
Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian untuk Pembersih Perhiasan Ultrasonik Audiodesksysteme Gläss Vinyl Cleaner PRO. Audiodesksysteme Gläss Vinyl Cleaner PRO 14 halaman.
Juga untuk Audiodesksysteme Gläss Vinyl Cleaner PRO: Panduan Petunjuk Pengoperasian (13 halaman)
7
Cleaning liquid
CAUTION !
Keep the concentrated cleaning liquid away from children.
The cleaning liquid must remain in the device for more than 4 weeks.
The cleaning liquid consists of distilled or demineralized water and concentrated cleaning liquid.
The liquids are mixed together inside the water tank.
- Distilled or demineralized water can be purchased in shops.
- The concentrated cleaning liquid can be purchased from the manufacturer.
8
Changing the cleaning liquid
CAUTION !
Never allow children to change or refill the cleaning liquid.
Pull out the mains plug of the power supply unit from the power socket before changing the liquid.
Wipe up any leaked fluid immediately.
Approx. 100 records can be cleaned with one bottle of concentrated cleaning liquid,
depending on the amount of dirt.
8.1
Emptying the device
1. Place the device above a suitable bowl or sink.
- The collection bowl must be able to hold at least 4.5 liters of liquid.
2. Open the drain plug (8).
- In order to empty the device completely, tip the device slightly backwards and to the side.
3. Screw the drain plug back in again and tighten it.
8.2
Filling the device
For each filling operation, the following are required:
- 4.5 liters of distilled or demineralized water
- 1 bottle of concentrated cleaning liquid
NOTE !
!
Only use the original cleaning liquid! Other cleaning agents may cause
malfunctions or irreparable damages to the device (e.g. due to excessive
foaming, attacking the water level window) or damage the record. The
original concentrated cleaning liquid also prevents the record from becoming
electrostatically charged. No liability is assumed for damage to the device or
records if this warning is disregarded. Furthermore, the warranty will be thereby
invalidated.
1. Fill the clean cleaning liquid into the rinsing chamber (6).
- The cleaning barrels do not have to be removed.
- The float must reach the upper edge of the level indicator (3).
Due to evaporation, the filling level may become insufficient to start the cleaning process
(LED (13) lights up red). Top up with some distilled or demineralized water.
V 1.0/2016 Page 10 of 14