Cabling

CAT5
The DCS 6000 system uses CAT5, CAT5e or
CAT6 FTP or STP cables with screened RJ45
connectors.
EIA 568-B wiring shall be used.
It is important to use only FTP or STP
(screened) cables and screened RJ45 connectors
and not UTP cable, which is unscreened.
How to wire a CAT5 (EIA 568-B) Cable:
Pin Function
Connector
1
In-going +
ORG/WHT
2
In-going -
ORG
3
+48V
GRN/WHT
4
0V
BLU
5
0V
BLU/WHT
6
+48V
GRN
7
Outgoing -
BRN/WHT
8
Outgoing +
BRN
Note.
If other colour codes are used then the four
pairs are connected as follows:

Technical specifications

General
Power consumption ..................................................max. 0,5W
Supply voltage for unit's ..................................................... 48V
Temperature to guarantee specified performance
..............................5 Deg C. to 40 Deg C. (35 to 80% humidity)
Storage temperature
.......................... -20 Deg C. to 60 Deg C. (10 to 80% humidity)
Weight JB 6002 ............................................................... 0,1 Kg
10
#1
Connector #2
ORG/WHT
ORG
GRN/WHT
BLU
BLU/WHT
GRN
BRN/WHT
BRN
Manual 01 18 04453
Pair 1:
Pin 1 & 2
Pair 2:
Pin 3 & 6
Pair 3:
Pin 4 & 5
Pair 4:
Pin 7 & 8
The phase of the pairs must be correct and
the wiring spec. as stated in CAT5 (EIA
568-B) have to be followed.
Note: CAT6 cables can normally only be
terminated in sockets (female) and not in cable
plugs.
CAT6 can thus only be used for longer cable draws
terminating in wall outlets or jack patch panels.

Accessories (not supplied)

Cat 5e Connection Cables (AWG24)
EC 6000-..5 Connection Cable 0,5 m......................10 03 12500
EC 6000-01 Connection Cable 1 m.........................10 03 13101
EC 6000-02 Connection Cable 2 m.........................10 03 13201
EC 6000-05 Connection Cable 5 m.........................10 03 13501
EC 6000-10 Connection Cable 10 m.......................10 03 14102
EC 6000-20 Connection Cable 20 m.......................10 03 14202
EC 6000-50 Connection Cable 50 m.......................10 03 14502
Weight JB 6004................................................................0,2 Kg
Dimensions JB 6002 (W x H x D) ................80 x 24 x 102 mm
Dimensions JB 6004 (W x H x D) ................88 x 47 x 105 mm
Connectors
DCS-LAN loop through........................................2 pieces RJ45
DCS-LAN chain (JB 6002)...................................2 pieces RJ45
DCS-LAN chain (JB 6004)...................................4 pieces RJ45