When setup is complete, the display should
look like the right-hand screenshot. If any-
thing went wrong, repeat the process.
Tap the pencil icon to assign an individual
name to the new device.
If you have previously created a profile with
rooms, you can assign the device to a room.
Tap the desired room under the name of the
device so that it is highlighted with a dark
background.
Finally, tap the blue lettering at the bottom to
complete the setup.
The newly added device will be displayed on
the main page (see the first screenshot in the next section).
The device assigned to a room will appear under the respective room.
If you tap to switch to a room, you will only see the devices that are linked to that room.
9 Operation in the app
Tapping on the device on the app's main
page opens the page with advanced features
and settings.
You can delete the device from the app by
tapping on the device on the main page un-
til the delete button appears on the display
below.
Then tap the button and confirm.
The product page always shows the current
temperature, humidity and CO
concentration
2
values.
It also shows the battery status.
You can also set the display brightness and
adjust the alarm volume.
Tapping the button at the top right below the
name shows the measured data in a diagram.
Tapping the pencil icon at the top right opens
the current device's general settings. These
settings are available for each unit linked to
the app.
Here you can update the firmware or create a
shortcut on your home screen.
Tapping the arrow at the top left takes you
out of the control page and back to the app's
main page.
10 Cleaning and care
Important:
– Never use aggressive detergents, rubbing alcohol or other chemical solutions, as the-
se could damage the housing or even impair the functioning of the product.
– Do not immerse the product in water.
1. Disconnect the product from the power supply.
2. Use a damp, lint-free cloth to clean the product.
11 Disposal
This symbol must appear on any electrical and electronic equipment placed on the
EU market. This symbol indicates that this device should not be disposed of as
unsorted municipal waste at the end of its service life.
Owners of WEEE (Waste from Electrical and Electronic Equipment) shall dispose
of it separately from unsorted municipal waste. Spent batteries and accumulators,
which are not enclosed by the WEEE, as well as lamps that can be removed from
the WEEE in a non-destructive manner, must be removed by end users from the
WEEE in a non-destructive manner before it is handed over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free take-back
of waste. Conrad provides the following return options free of charge (more details on our
website):
in our Conrad offices
at the Conrad collection points
at the collection points of public waste management authorities or the collection points set
up by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply in
countries outside of Germany.
12 Declaration of Conformity (DOC)
Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau hereby declares that this
product conforms to the 2014/53/EU directive.
Click on the following link to read the full text of the EU declaration of conformity:
conrad.com/downloads
Enter the product item number in the search box. You can then download the EU declaration of
conformity in the available languages.
13 Technical data
13.1 Power supply
Input voltage ................................. 5 V/DC
Power consumption ...................... max 1 A
Input.............................................. USB Type-C
Battery (built-in) ............................ rechargeable lithium polymer battery, 3.7 V, 2000 mAh
Battery life ..................................... min. 12, max. 18 hours
13.2 Thermohygrometer with CO
Product life .................................... max. 10 years
Display .......................................... LED
Temperature display range ........... 0 to +65 °C
Temperature resolution ................. ± 1 °C
Humidity display range ................. 0 – 99% RH
Humidity resolution ....................... ± 5% RH
CO
display range ......................... 400 – 5000 ppm
2
CO
accuracy ................................ ± (50 ppm + 5%)
2
CO
resolution .............................. 1 ppm
2
13.3 Wireless module
Wi-Fi ............................................. IEEE802.11b/g/n, 2.4 GHz
Frequency ..................................... 2.412 – 2.472 GHz
Transmission power...................... <20 dBm
Wi-Fi range ................................... max. 100 m (in open space)
13.4 Miscellaneous
Supported operating systems ....... Android
Dimensions (W x H x D) ............... approx. 100 x 100 x 30.5 mm
Weight .......................................... approx. 158 g
13.5 Ambient conditions
Operating temperature ................. 0 to +65 °C, 0 – 99% RH (non-condensing)
Storage temperature ..................... 0 to +70 °C, 0 – 99% RH (non-condensing)
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
Copyright 2023 by Conrad Electronic SE.
6
TM
detector
2
6.0 or later; Apple iOS 10.0 or later
TM
*#2884220_V1_0723_02_m_VTP_EN
www.