Danner PONDMASTER HAMPTON CPF2000U Petunjuk Perawatan dan Pengoperasian - Halaman 7

Jelajahi secara online atau unduh pdf Petunjuk Perawatan dan Pengoperasian untuk Sistem Penyaringan Air Danner PONDMASTER HAMPTON CPF2000U. Danner PONDMASTER HAMPTON CPF2000U 11 halaman. Pressurized filter system

8

FILTER MAINTENANCE

The debris filter pad is first to receive the water that is pumped into the filter. When the debris filter begins to clog it can be
removed and rinsed or replaced completely. If you choose to rinse the debris filter, rinse with water taken from the pond instead
of chlorinated tap water. Doing this will avoid killing off the useful bacteria colonies that grow on the filter pads.
Conditions vary, but generally the Biomatrix Ball Media will begin to grow helpful bacteria in a few weeks. Once established, these
should not be disrupted during the warm weather season.
QUICK DISCONNECT / FLOW CONTROL VALVE INSTRUCTIONS
The intake and outlet are mounted to a
removable Quick Disconnect / Flow Control
valve.
The Blue Lever will adjust flow rate as well as
shut off the hoses allowing you to leave them
attached to the valve assembly at the pond
while servicing the filter case.
1) Turn off pump.
2) Pull Lever forward. This will close off flow in
both hoses inside the valve.
3) Pivot the Lever to the right - this unlocks
the Quick Disconnect Valve.
4) Pull Valve assembly straight upwards.
PULL LEVER
A
FORWARD
IMPORTANT!
CPF2000/PF1900 series
includes pressure release knobs
on both sides of the cover. Once
the corner latches are in the
open position, rotate both of
the knobs counter clockwise to
break the seal and lift the cover.
IMPORTANT! ALL MODELS:
9
WINTERIZATION
These filters are intended for use in non-freezing environments. If used in areas with cold winters, they must be
removed from service, dried and stored before the freezing weather occurs. Failure to do so will void the warranty.
TOP VIEW OF VALVE ASSEMBLY
BLUE LEVER UP:
Maximum ow.
A
B
C
D
ILLUSTRATION SHOWN WITHOUT HOSES FOR DEMONSTRATION
B
1) Always keep connection surfaces of valve assembly, cover and filter case clean
of any dirt, sand or debris before reassembling.
2) During reassembly press Quick Disconnect / Flow Control Valve completely down into
filter cover before pushing lever back to left and up into maximum flow position.
MOVE BLUE LEVER DOWN:
Reduced ow down to no
ow/ Valve closed.
PIVOT LEVER
TO THE RIGHT
C
Always keep Cover O-Ring and contact surfaces of cover and filter
case clean of any dirt, sand or debris before reassembling.
7
For Models CPF 250, 500, 1000
PF 225, 450, 900
BLUE LEVER DOWN & PIVOT
TO THE RIGHT: Valve closed
and unlocked for removal.
LIFT
VALVE
ASSEMBLY
D
REMOVE VALVE WITH
HOSES ATTACHED