1.3. Operating principle
The PLSG10000 is designed for use in alarm and home automation systems using the Z-Wave radio
standard. The device has the following functions:
Alarm Activation:
When the siren is activated by the Z-Wave Gateway, the unit's piezoelectric siren sounds for 3
minutes (default) along with the flashing LED.
Audio playback:
It is also used to play audio files from the built-in speaker.
The user can download audio files from the PC to the unit's memory and play them back using
commands from the Z-Wave controller. In addition, the device memory already contains useful
files and further language files in German and English are available for download under :
www.abus.com/product/PLSG10000
For example, you can be informed about fault messages, such as low battery status of a
component, or status changes of the system, e.g. activation or output delay.
With integrated temperature and humidity sensor
Sabotage protection between siren and wall mount. In case of sabotage, the second audio file of
the list is played, by default a sabotage alarm.
1.4. Performance characteristics
The device...:
...is a battery-powered indoor siren
...is only suitable for wall mounting due to its construction type
...is Z-Wave PLUS compatible & certified
...supports the Z-Wave S2 standard (Security 2)
...has a battery-empty warning function
...was developed for indoor installation
1.5. Use in systems of different manufacturers
Communication takes place via the Z-Wave EU frequency (868.4 Mhz). You can integrate the device
into any Z-Wave network with a certified Z-Wave gateway, regardless of the manufacturer. All non-
battery nodes in the network act as amplifiers to amplify the radio communication of the network.
1.6. DSK Code
The DSK Code (Device-Specific-Key) is the device-specific key of your device and is required for secure
teach-in (including) via S2 at the gateway. The first 5 digits of the DSK code can be found on the bottom
of the product. Please enter these in the inclusion process when prompted. Alternatively, you can
transfer the entire DSK code found on the enclosed DSK card to the gateway via QR code scan. Please
keep the DSK card in a safe place!
Hint:
We recommend secure S2 inclusion (must be supported by the gateway) Please enter the 5 digits of
the DSK code (bottom side of the device) or the entire DSK code (QR code) when prompted.