Audiophony PA AMP4240 Panduan Pengguna - Halaman 7

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Penguat Audiophony PA AMP4240. Audiophony PA AMP4240 12 halaman. 1x480/4x120/4x240w pa amplifiers with 1 or 4 x 100v outputs

Audiophony PA AMP4240 Panduan Pengguna
AMP480/4120/4240 - 1x480/4x120/4x240W PA amplifiers with 1 or 4 x 100V outputs

4 - Using your amplifier

CAUTION: Please make sure your amplifier is not plugged in and is OFF when checking cables.

Input connectors

The line-level plug (INPUT) and LINK output are balanced.
However, they can still receive unbalanced signals.
You can also send the incoming signal from one way to another one as described below:

Output terminals

Please use high-quality cables to connect your speakers.
In order to prevent short-circuits, please tin the cables before connecting them to the output terminal.
You will find below a table of correspondence between the amplifier/speakers distance and cable sections in
order to prevent signal quality losses.
Distance
Up to 8 m
Between 8 and 12 m
Between 12 and 18 m
Between 18 and 30 m
Between 30 and 45 m
Between 45 and 60 m
Note: Never use screened cable to carry amplified signal.
Section
1,5 mm²
2 mm²
3,5 mm²
5 mm²
8,5 mm²
13 mm²
Page 7