Consort CN2MLSTRX Manual - Halaman 2
Jelajahi secara online atau unduh pdf Manual untuk Pemanas Consort CN2MLSTRX. Consort CN2MLSTRX 2 halaman. 2 kw low surface temperature heaters for wireless control
O
PERATION
This heater can only be used when connected to a CRX2 wireless programmable timer.
Each CRX2 can control any number of heaters. The heater has an indicator light positioned on
the fascia panel. The light may be:
Green
-
when no heat is needed
Yellow
-
when some heat is needed to maintain the room temperature
Red
-
when the heater is on full power
Fast Flashing Red
-
when the heater has overheated and the Electronic Safety Control
has switched the heater off.
Please refer to the CRX2 user and operating instructions for full operational details.
C
M
S
ONNECTION TO THE
AIN
UPPLY
Electrical installation should be carried out by a competent installer, preferably registered
with NICEIC (National Inspection Council for Electrical Installation Contracting) in accordance
with the 16 edition of the IEE Wiring Regulations, (BS.7671: 1992), and any relevant Local
Authority Bye-Laws.
This heater is fitted with a 3-core mains supply cable and should be permanently
connected to the electricity supply via a double pole switch having 3mm gap on each pole.
A switched Fused Connection unit to BS.1363. Part 4 is a recommended mains supply
connection accessory to ensure compliance with safety requirements applicable to fixed-
wiring installation.
E
S
C
LECTRONIC
AFETY
ONTROL
The appliance is fitted with an Electronic Safety Control (ES). This is a safety device which
switches the heater off if, for any reason, the appliance overheats. The overheating is
indicated by a fast flashing red light. The ES control can only be re-set after the appliance has
cooled down. In order to re-set the ES control, proceed as follows:
Switch the appliance
off at the mains by using
isolator switch and leave
to
cool
down
for
approximately
5
minutes.
Switch appliance back
on and the ES control
will re-set.
Ensure
that
the
appliance is functioning
correctly.
If the ES
control operates again,
the appliance should be
checked by a competent
electrician.
62001210 Iss 02
W
M
ALL
OUNTING
The heater must not be located
immediately
below
a
fixed
socket
outlet.
The Wall Mounting bracket is packed
separately in the carton.
Fit the mounting brackets to the wall at
the height and centers shown in
the diagram.
Rest your appliance on the bottom of
the mounting bracket and secure with
the two top locking screws including the
plain washers. Do not over tighten.
Now secure the appliance with two
bottom locking screws including plain
washers. Do not over tighten.
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: ALWAYS RETAIN YOUR USER INSTRUCTIONS FOR FUTURE REFERENCE
S
AFETY
This equipment has been designed and manufactured to the highest international
standards, but, like all electrical appliances which are operated by mains voltage, care must
be taken if you are to obtain the best results and safety is to be assured.
NOTE: The appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge unless they have
been given supervision or instruction concerning use of the appliance by a person responsible
for their safety.
Children should be supervised to ensure that they do not play with the appliance
Do NOT site the appliance into a corner.
Do NOT site this heater in the immediate vicinity of a bath, a shower or a swimming
pool.
Do NOT operate the appliance with wet hands.
Do NOT use the appliance in workshops or rooms where excessive dust is generated
or present.
Ensure that nothing is pushed into any aperture of this appliance.
Do NOT touch outlet grille when the appliance is in use.
(NB: the LST heaters have a maximum surface temperature of 43
Do NOT cover or restrict any aperture of the appliance when in use.
Do NOT use the appliance if damaged.
Do NOT leave the appliance unattended where young children are present.
This appliance meets the requirements of EU Directive 89/336 for EMC.
0
C)