Dantherm CD 400-18 Buku Petunjuk - Halaman 18

Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Dehumidifier Dantherm CD 400-18. Dantherm CD 400-18 19 halaman.

Dantherm CD 400-18 Buku Petunjuk
Specifications
Model
PowerSupply
Dehumidity Capacity
Power Consumption
Capacity of water tank
Weight
Dimensions
Room Temperature
Trouble- Shooting
Prior to requesting to repair, please check for the following:
Malfunction
Check
disconnected.
Check if the water tank is full of
No operation
Check if the water tank is not set
Check if all the flaps are closed.
Check to see if the air openings are
Dehumidified
volume is small
Check if the dehumidifier is in air
Loud sound
while operating
Operation stops
Check if the room temperature is
during spot
higher than the usable operating
dehumidifying
Check if washed clothes are not
Washed clothes
exposed to the air from the unit.
are not dried
Check if the room temperature is too
17
CD 400-18
220V-240V (50Hz)
18 ltr./24 hours (30℃/80 % RH)
340W
Approx.4,5 L
13kg
Height 575mm, Length380mm, Width 225mm
5℃-35℃
Points to be checked
if
the
power
water.
properly in position.
Check if the filters get dirty.
blocked up.
clean mode.
Check to see if the unit is not
installed as specified.
temperature.
low.
The specification may be subject to change
without notice for purpose of improvement.
Measures to be taken
Insert the plug into an electric outlet fully
plug
is
Empty the water out of the tank.
Set the tank to the unit properly in
Open one of the flaps.
Clean the filters as specified.
Remove obstacles from the air openings.
Change the operation mode to the
dehumidifying mode.
Install the unit on a level and stable floor.
The dehumidifying operation will be
started automatically when the
Try to expose the washed clothes to the air
Washed clothes are hard to be dried under
low temperature conditions.
and securely.
position.
temperature lowers.
flow.
Ref.Page
2
2
11
13
13
13
13
13
13
13
13