might find that the unit sounds substantially better in the "Engaged" position. If this is the case, it is possible
that the main or primary power amplifier is not plugged into High-Current AC bank 1, the power amplifier has
insufficient current draw to activate the circuit, or the circuit is miscalibrated.
When the Power Correction switch is set to the "Engaged" position, the current sense circuit will be defeated. Yet,
even with the current sense circuit functioning properly, audiophiles may prefer the "Engaged" position, as it will
slightly decrease the impedance of the Transient Power Correction Circuit.
My Niagara 7000EU has no power amplifiers connected to it, but it sounds odd or
not quite as good as it once did.
The Transient Power Correction Circuit also aids the Ultra-Linear Noise-Dissipation Circuits. Make certain that
the rear-panel Power Correction switch is in the "Engaged" position.
A technician or electrician found that my Niagara 7000EU consumes over 8 amps
of current. Is it broken?
No, it's not broken, and it's not drawing 8+ amps in any conventional sense. The Niagara 7000EU's Transient
Power Correction Circuit creates a reactive current draw of as much as 9 to 10 amps RMS at idle, and, when
incorporated with power supplies such as those found in power amplifiers, the current readings decrease. This
is a vector load, which will vary with the connected equipment. When plugged into an AC service that has no
other electrical draw, it is typical to see a real-world RMS power draw well below 15 watts at idle. (For an in-
depth explanation of the circuit, see "Power Correction Switch.")
I did not notice hum with any prior power device, but there is a hum in my system
with the Niagara 7000EU.
Typically, this will not occur. In fact, the Niagara 7000EU's two Ultra-Linear Dielectric-Biased Symmetrical Power
outlet groups are 100% isolated from one another, 100% isolated from the High Current/Power Correction outlet
group, and floating. This allows opportunities to break up ground loops in an audio system. However, the hum
created by ground loops (typically, a voltage differential from Neutral to Ground among two or more signal-
connected devices in an audio/video system) can at times be quite complex and difficult to easily diagnose.
To diagnose the hum/ground loop: With everything else unplugged, start with the simplest system that can still
play music through your loudspeakers. Use a source such as a universal player, computer, or a turntable so there
is no external cable or satellite cable connected to ANY of the associated components. Is there any hum? If yes,
and there is more than one line-level (non-power amplifier) component connected in this "minimalist" test, try
placing one in Symmetrical Power group one and the other in group two.
If the hum no longer persists under these conditions (which is likely), try reconnecting each additional component
into the Niagara 7000EU one at a time. Once you find the component that creates the hum, you can possibly
achieve increased isolation by connecting it to a different Ultra-Linear/Symmetrical Power outlet group. This
can typically help, as well as increase overall system performance by decreasing system noise. If adding a cable
or satellite signal to the system reintroduces the ground-loop hum, that incoming signal line may require an
isolation transformer or humbucker.
If it seems that hum didn't occur before, but does now, it's most likely that the hum was in fact always there. The
difference is simply a matter of degree. Sometimes the ground loop difference is right on the edge of breaking
into an area where it's audible, instead of only measureable with electronic measurement instruments. The
very act of creating better connections, thus minimizing the impedance to the power amplifiers, can tip the
scales. If the hum/ground-loop exists on the incoming satellite or cable line, then it will be necessary to fix the
real problem. This is common with large custom install systems. As these signal lines are always grounded in a
different place and at a different potential than the rest of the system's ground return, the system will benefit
greatly by utilizing isolation under these conditions.