Symptom
There is no power
detected through
amplifier (and there is
power at the socket).
Amplifier goes into
feedback.
Unit does not go into
power saving mode.
Factory Default Settings
To return to the factory default settings:
1.
Unplug the power supply and then reconnect it.
2. Press the On/Off button and Volume In (-) button together, then release.
3. The Volume In LED bar will have all LEDs illuminated, while the Volume
Out LED bar will display the firmware revision number in a fixed pattern
of LEDs. This indicates that default settings have been restored.
If the amplifier detects an error in its' settings memory it will restore itself to
factory default settings.
Our Window Intercom System amplifiers are pre-set to provide the
recommended output for most environments. Should you need to adjust
the Volume, Ducking or Hearing Loop levels outside of the pre-set amplifier
parameters, you can do this by entering Engineers Mode (see pages 6 & 7).

Troubleshooting

Possible Fault
1) Power jack not plugged in or
faulty.
2) Plug fuse has blown.
3) Faulty power supply unit.
4) Faulty amplifier.
1) Internal volume gain set to high.
2) Microphone positioned too close
to speaker.
1) Ambient noise in area is too high.
Action
1) Check power jack is firmly plugged in.
2) Replace fuse, but if it blows again
contact your supplier.
3) Replace the power supply unit.
4) Replace amplifier.
1) Access the amplifier engineers mode to
adjust the internal settings.
2) Move the microphone to a location
further from the speaker.
1) Switch off any air con systems, desktop
fans and or computers to reduce ambient
noise.
5