Higher CFM airflow reaches further in
the room.
!
Dead zones or area's of air stagnation occur:
- in upper and lower corners of a room.
- behind the HEPA Tower, more so if not placed against a wall.
- when the airflow is too low for the room size.
!
- when there is furniture in the room obstructing the air path.
Proper operation and placement of the HEPA Tower can be achieved by applying the basic information,
previously described. Physically "feeling" the reach of the airflow and direction should give the
operator a good idea about the airflow through the room. Use speed adjustment in conjunction with a
directing the exhaust louvers to create a proper airflow path that fills the room flowing from high to low.
!