4B HTAS1V34 Panduan Pengoperasian - Halaman 12
Jelajahi secara online atau unduh pdf Panduan Pengoperasian untuk Aksesori 4B HTAS1V34. 4B HTAS1V34 20 halaman. Wda sensor belt alignment / motion & broken / slack chain monitor
PLASTIC ELEVATOR BUCKET MOUNTING DIAGRAMS -
NORMAL RUNNING
Plastic Elevator Bucket
PULSE
If using stainless steel
bolts (non-ferrous), use
PTFE coated steel fender
washers (ferrous) between
the belt and bucket.
Potentiometer Sensing Range
PULSE
Bolt Head
Elevator
Trunking
WDA
Mounting
Block
WDA Sensor
Adjustment Screw
BELT MISALIGNMENT
NO PULSE
Figure 6 -
WDA Sensor Placement For Plastic Elevator
Buckets (Detecting Bolts) On Up Side Of Leg
1/2 in.
to
1 in.
PAGE 12
Plastic Elevator Bucket
PULSE
Plastic Elevator Bucket
Approximately
1-1/2 inches
Figure 7 -
WDA Sensor Installation
For Plastic Buckets