APlusLift HW-8SXLT Panduan Pemasangan & Pengoperasian - Halaman 11

Jelajahi secara online atau unduh pdf Panduan Pemasangan & Pengoperasian untuk Sistem Pengangkatan APlusLift HW-8SXLT. APlusLift HW-8SXLT 19 halaman. 4-post portable storage car lift

Step 6 (Electrical Connection to Power Unit)
• Warning: T
electrician to connect the power unit to a 110V power outlet. Please
protect each circuit with a time delay fuse or circuit breaker.
• The car lift uses a 110V single phase power unit. The running amperage is 10A.
Recommend a 30A breaker and a 10-gauge wire.
• For 110V single split phase with two hot wires:
wire brown to hot 1
wire blue to hot 2
wire yellow/green to ground
• For 110V power with one hot and one neutral wires:
wire brown to hot
wire blue to neutral
wire yellow/green to ground
• See the figure on the right for reference.
he wiring must comply with local code. Please find a certified
11