Advanced Battery Settings
Enter Load SET Mode by pressing the Setting key in Load Mode view only.
Use the arrow key to cycle through load modes before long pressing SET to save and exit. Short
pressing SET will exit without saving.
Mode
0
Daylight Auto-Control
1~14
Daylight On/Timer Off
15
16
17
Definition
Manual Mode
Testing Mode
Always On
Description
DC load turns on when daylight is detected.
DC load turns on when daylight is detected.
DC load turns off according to timer.
DC load turns on/off by pressing the Return key.
DC load turns on and off in a quick succession.
DC load stays on.
16