DaSeDa Electronics HM-710A Manual - Halaman 11

Jelajahi secara online atau unduh pdf Manual untuk Pengontrol DaSeDa Electronics HM-710A. DaSeDa Electronics HM-710A 15 halaman. Digital feeder controller

11. How to operate the volume
When the parameter value is increased or decreased by the volume of HM-75A (frequency, voltage, DELAY TIME, etc.)
Change unit can be changed to 0.1 or 1.0.
The default is 0.1, and when you press the volume button, it becomes 1.0 units.
Every time you press the volume button again, 0.1 -> 1.0 -> 0.1 ...
In the display, the corresponding unit number flashes.
0.1 unit
If it is 1.0 unit
11-2. Communication ID setting
The HM-75A is connected to an external device such as a computer via 485 communication to transmit data such as the status and parameters of the controller.
You can control the parameters and operation of the controller from an external device.
The communication method is 485 system. Up to 32 controllers can be connected to one external computer or control device.
You can connect and control at the same time.
To do this, you need to give an ID for each controller, so how to set the ID is explained.
Turn the selector to set it to "Communication ID setting" mode and set the ID to volume, or set the communication function
It can be stopped.
The setting value is 0 ~ 32, 0 is when communication function is not used ("oFF" is displayed)
However, if you connect multiple controllers together, you must set a different ID for each controller.
If there is a duplicate ID, the controller can not communicate.
Turn the selector
Set to communication ID setting mode.
If you turn it left
Press the selector button
Turning the volume
0 case
10 cases
If you turn it right
Change the volume to the desired value.
(Setting range: 0 ~ 32)