DaSeDa Electronics HM-75A Manual - Halaman 13
Jelajahi secara online atau unduh pdf Manual untuk Pengontrol DaSeDa Electronics HM-75A. DaSeDa Electronics HM-75A 15 halaman. Digital feeder controller
13. Product Features and Specifications
Item
Rated input
How to set up
volt
Setting range
Out
How to set up
put
frequency
Setting range
Met
Maximum capacity
hod
Driving method
Control method
External input
on / off
Control
driving
stop
OVF
Control
Sensor input
Pause
Con
Control
trol
Met
Panel manipulation
hod
Vibration Width Control
Analog input
amplitude
Control
External volume control
2CH selection control
Operation synchronization signal
Soft Start
Soft Stop
Memory function
Access restrictions
7 -Segment
Disp
Operation status LED (Red)
lay
Parameter LED (green)
Communication function
Protection function
Cooling system
Ambient temperature
Terms of Use
Ambient humidity
weight
Specifications
Appearance
HM-75A
AC 90 ~ 260 (50Hz/60Hz)
Turn volume right and left, external volume, 0 ~ 5V control signal
0 to 200 V (unit 0.1 V)
Turn volume right or left
40 to 400 Hz (unit: 0.1 Hz)
5 A
PWM method
Full digital control by microcomputer
On / off control by external input
Voltage input control (+12 ~ + 24V)
Input polarity setting (no, nc)
On Delay Timer setting: 0.0 ~ 60.0sec, 0.1sec unit
Off Delay Timer setting: 0.0 ~ 60.0sec, 0.1sec unit
Pause / Move in RUN state
Change input settings: no, nc
Up to 3 sensors can be used. (3 sensor input terminals)
On Delay Timer setting: 0.0 ~ 60.0sec, 0.1sec unit
Off Delay Timer setting: 0.0 ~ 60.0sec, 0.1sec unit
Sensor power: DC12V
RUN,STOP Key
Feed-back control by vibration sensor
Automatic frequency setting function
Output voltage control with DC 0 ~ 5V input
Output voltage control with external volume connection
V1 / V2 selection operation by external input (2-step control)
V2 on / off setting from menu.
3 terminal (COM, NC, NO) contact output
Slow Up Timer: 0.0 ~ 3.0sec, 0.1sec unit
Slow Down Timer: 0.0 ~ 3.0sec, 0.1sec unit
Voltage, Frequency, Parameter READ / WRITE
Data change input prohibition function (when RUN key is pressed for 3 seconds)
Display voltage, frequency, parameter and error code
RUN,Feed-Back,
Parameter item display (frequency, voltage, sensor, external input, etc.)
485 communication control
Over-current, over-temperature operation stop and error indication
Natural air cooling
0 ~ 40'C
10 ~ 90%
1.25Kg
68(W) X 100(D) X 147(H)
HM-710A
10 A
2.4Kg
98(W) X 100(D) X 147(H)