INSTALLATION

To operate a good installation of the gear motor
BIG FOOT follow these instructions:
Locate inside the property the correct point to
install BIG FOOT, usually near to the support
column of the gate.
Assemble the support plates "Pb" with the
anchorage pins and adjusting grubs
Build up a cement emplacement with sizes like fig.
3, foreseeing the passing of the protective
coverings "G" for the passing of the power supply
and control system cables.
Before the cement solidifying, install the bracket
"Pb" immersing the anchorage pins in the cement
and making sure that the bracket "Pb" is oriented
and perfectly on level
After that the cement will be perfectly solidified
install the gear motor BIG FOOT on the bracket
"Pb" and after removing the protection cover fix the
operator softly by supplied nuts "Vf"
Loose the screws "Vp" and make the operator BIG
FOOT run in the suitable holes to establish a
distance between the operator's pinion "P" and the
gate suitable to the type of rack "C" you want to
install. The tooth of the pinion must mesh with the
teeth of the rack for all its width, so fix the nuts "Vf"
(fig.
5).
Carry out an emergency or manual manoeuvre
(see the par. " Emergency or manual manoeuvre")
and put the gate in the maximum opening position.
Lean one end of the rack "C" on the pinion "P",
make sure that it's horizontal and fix it by welding
or by the suitable screws "Vc"
make slide the gate, checking that the rack don't
force on the pinion and that don't go away.
If the gate is crooked put between the gate and the
rack some thickness to assure the constant
centring between the rack and the pinion.
After fixing definitively the rack "C" loose slightly the
nuts "Vp" and adjust the play-gap between rack and
pinion (2 mm apron.) using the grubs "Gr" to
position correctly the operator
When everything has been done fix the nuts "If"
and the nuts "D1" and with a manual manoeuvre
open and close the gate to verify the correct
alignment (there have not been friction).
IMPORTANT
The duration of the rack and the pinion depend
on the right mesh engagement.
In view of the considerable weight of the gates
we recommend to use iron racks or steel racks
with an adequate thickness.
(fig.
1).
(fig.
3).
(fig.
4).
(fig.
6), fixing the rack
(fig.
7).
The gates must have mechanical stops "Fa"
(fig.
8) in opening and closing to avoid its
derailment.
The mechanical stops "Fa" must ensure an
antic rushing space between the mobile and fix
part of the gate, in conformity with the
regulations in force.
Put the gate in opening position and, according to
the gate weight, leave a space of 30-50 mm
between the gate and the mechanical stop "Fa"
8). Fix on the rack the limit switch support "S" by
grubs "Gr1"
(fig.
9) in order to push the limit switch
(fig.
9-b).
Repeat the same operation on the other side, for
the closing limit switch support.
Make the circuitry like in the control panel manual
and install the obligatory safety devices.
Teach the people intended for the use of the
automation about the controls, safety devices,
emergency manoeuvre and dangerousness
deriving from the utilize of the automation.
Compile the technical booklet and fulfil the
eventual obligations deriving from the regulations
in force.
We Guartntee the correct functioning of BIG
FOOT versions only and exclusively if provided
by DASPI
and only if combined with the
original control panel.
EMERGENCY OR MANUAL MANOEUVRE
You have to do the emergency or manual
manoeuvre or during the installation, or only if the
automation does not work properly or if there is not
power supply.
CUT OFF THE POWER SUPPLY.
Open the plug on the handle "LS" cover and insert
the supplied key "CH"
Turn the key "CH" anticlockwise and take out the
handle of 90° towards you
gate manually.
In order to re-establish the normal functioning of
the automation, you have to put again the handle
"LS" in the original position and turn the key "CH"
clockwise, so take away the key and close the plug
on the handle.
Place the key "CH" in a safety place known
exclusively from the people intended for the use of
the automation.
Switch on the power supply, pay attention that
there's nobody where the gate is moving.
(fig.
10).
(fig.
10) and open the
(fig.