4EVAC Compact 500 operation manual
7. Technical specifications
Standalone system
Number of zones
Maximum total loudspeaker load
Power amplifiers
Standby power amplifiers
Loudspeaker line monitoring
Built-in
Loopdrive
Loudspeaker type
Voice messages
Storage
Message player
Controls and indications
General controls / indications
Fault indications
Zone controls / indications
Evac manual control
Fireman microphone
Power supply equipment
AC supply
AC current consumption
Inrush current
Power supply protection
Battery requirements
Type
Capacity
Charging time (80% capacity)
Rated voltage
Battery dimensions
Battery weight
Inputs
2 x BGM
6x EVAC in, 1x SILENCE in, 1x RESET in
8 x GPI
Outputs
EVAC out, FAULT out
GPO
Loudspeaker out
Amplifiers
Type
Protection
Backup amplifiers
Efficiency
Output voltage
Page 11 of 15
max. 6 local zones
600 W RMS (420W RMS pure sinewave according to EN54-16)
6 x 100 W, modular (2 channels per module), bridgeable up to 3 x 200 W
2 x 100 W / 1 x 200 W dedicated backup amplifiers
20kHz AC monitoring with EOL module, short/open/impedance deviation
loop DC monitoring with short-circuit isolators, short/open/earth leakage, EN54-
17 certified
with 100V step-down transformer
max. 16 audio files x 1 minute each, micro-SD card with content monitoring
Max. 2 simultaneous local message playback
Lamp test button, silence button, power, evac, general fault LED indicators
Power supply, system fault, network, zone fault
6 x configurable zone selection button, zone EVAC/FAULT/BUSY LED indicators
EVAC message, ALERT message, SILENCE, RESET, fireman mic with PTT button
Integrated Fireman Mic with priority and electrical monitoring
Built-in power supply system, EN 54-4 certified.
110 – 230 V AC, 50/60Hz
max. 5.3A @115V AC / 2.65A @230V AC
20A @115V AC, 40A @230V AC
Overload current limiting, over voltage shutdown, over temperature shutdown.
Sealed, rechargeable lead-acid battery for stationary use
10 – 55 Ah
< 24 h
24 V DC (2 x 12V)
2 batteries, each of max. 230 x 138 x 207 mm (LxWxH)
max. total 32.6 kg
2 x independent balanced analogue in, line-level mono, 22kΩ input impedance
monitored logic inputs, 4.7kΩ +10kΩ EOL resistors
unmonitored logic inputs (pull-down, configurable active low/hi)
Potential-free relay output (configurable NO/NC)
8 x Open collector output (configurable NO/NC)
6 x 100V transformer output, 20 kHz AC monitoring with EOL
Class D
over load shutdown, over temperature shutdown
2 dedicated backup channels, auto backup at end stage failure, auto restore
80% @ rated power
max. 100V RMS