AddSecure 2 Series Panduan Instalasi dan Pemeliharaan Cepat - Halaman 4
Jelajahi secara online atau unduh pdf Panduan Instalasi dan Pemeliharaan Cepat untuk Sistem Keamanan AddSecure 2 Series. AddSecure 2 Series 9 halaman.
IRIS-4
2 Series
Quick Installation and
Maintenance Guide
6. InStaLLIng tHe IRIS-4 2 SeRIeS DIaLLeR
Use the following procedure to install the
IRIS-4 2 Series dialler:
6.1. Mounting
Choose a suitable location, taking into consideration
the routing of cables: power and panel dialler inter-
face . Remove the two case fixing screws under the
slide cover and open the unit, remove the two PCB
fixing screws and remove the PCB .
Position the housing on the wall and drill three
holes . Feed the cables through the opening at the
base of the plate, or via the 'knockouts', and secure
the plate to the wall with the three screws supplied .
6.2. Power
The IRIS-4 2 Series dialler can be powered using a
separate or Aux 9-28V DC power supply specified to
deliver a minimum 1A current using the screw termi-
nals indicated in Section 4 "Board Configuration" .
Note:
For Radio Equipment Directive compliance, the
power cable must be no longer than 3 meters in
length.
Fit the power cable. DO NOT APPLY POWER TO
THE DIALLER UNTIL INDICATED.
6
6.3. Connections
Connect cables to the PCB for the system as shown
in Section 4 "Board Configuration" .
• Ethernet enabled systems (IRIS-4 220 & 240):
Connect the 'ETH' connector using the Ethernet
cable to the local IP router/switch or socket that
has been allocated for the LAN/WAN network
IP connection .
• 2/3/4G enabled systems (IRIS-4 200 & 240):
Fit the supplied T-bar 2/3/4G antenna to the
'Cell Ant' connector but do not fix in place
until after performing the 2/3/4G network scan .
• Dial capture port (optional and for more infor-
mation see section below) .
• 4 x Pin Inputs (optional and for more informa-
tion see section below) .
Optional serial connection
The following three connections are optional and
depend on the panel connection method . By default,
the IRIS-4 2 Series RS485 connection is for Honey-
well Galaxy panels .
Note: For alternative panel manufacturers' selection,
use the touch screen Installers menu – settings to select
the option required. Please contact AddSecure for
further details or download the full panel installation
manual available from http://www.addsecure.com.
• RS485 currently available for Honeywell Galaxy
data bus (Alarms and Upload/download) or
Risco ProSys bus (Upload/download) connec-
tions (optional) .
• Serial TTL (optional).
• RS232 screw terminal (optional).
For more details on the cable requirements/connec-
tions please see details on next page .
RS485 ConneCtIonS (HoneYweLL gaLaxY oR RISCo PRoSYS)
IRIS-4 2 Series to Honeywell galaxy panels
IRIS RS485 Screw terminal
0V (Power)
VIN (Power)
A
B
IRIS-4 2 Series to Risco ProSys panels
IRIS RS485 screw terminals
0V (Power)
VIN (Power)
A
B
6.4. 2/3/4g SIM card (IRIS-4 200 & 240)
DO NOT FIT SIM card until after you have
performed the 2/3/4G Network Scan detailed
in the Section 6 . 8 "Configuration" . You will be
prompted when to insert the SIM card .
6.5. Dial Capture
Dial Capture enabled systems: Connect the two dial
screw terminals to the alarm panel dialler telecoms
line connection .
Note: Polarity is not important in this instance.
to
galaxy Data Bus terminal
←
→
Galaxy (-)
←
→
Galaxy (+)
←
→
Galaxy (A)
←
→
Galaxy (B)
to
Risco Bus1 terminal
←
→
COM
←
→
AUX
←
→
YEL
←
→
GRN
For EN50136-2: 2013 compliance fit the supplied
18kΩ sense resistor in parallel with the dialler output
of the alarm panel, at the alarm panel end of the
cable .
Note:
This resistor enables the dialler to detect cable faults
and/or tampers, the Monitoring Centre will also
need to enable the dial port monitoring on the IRIS
Secure Apps software to receive alarm notifications.
7