AddSecure IRIS-4 2 Series Panduan Instalasi dan Pemeliharaan Cepat - Halaman 8

Jelajahi secara online atau unduh pdf Panduan Instalasi dan Pemeliharaan Cepat untuk Sistem Keamanan AddSecure IRIS-4 2 Series. AddSecure IRIS-4 2 Series 9 halaman.

IRIS-4
2 Series
Quick Installation and
Maintenance Guide

8. SPeCIFICatIonS

transmission paths
200

Ethernet

Standard
Connection
IP addressing
Fault detection

2/3/4G

Frequencies
Penta band LTE (4G)
800/900/1800 MHz
2100/2600 MHz
Dual band UMTS (3G)
900/2100 MHz
Dual band GSM (2G)
900/1800 MHz
Connection
SMA socket for antenna
Fault detection
Loss of registration with network
IP
TCP ports (outbound)
53165 (Alarms & Polling), 51292 (Diagnostic & Reflashing), 10001 (Upload/Download)
Alarm transmission
Interface to
IRIS Secure Apps or IRIS Management Suite
Monitoring Centre
via EN 50136-2 pass-through mode
Dial capture interface
Two wire interface via terminal block
to alarm panel
Serial interface to
RS485, TTL, RS232
alarm panel
Note: RS232 cabling must not exceed 30 meters
PIN Inputs interface to
Maximum input voltage range 0V to +24V
alarm panel
Input 'low' (alarm) threshold < 1V
Input 'high' (restore) threshold > 2V
Internal pull-up impedance 10K to 3 . 3 V supply
14
220
240
UTP 10/100 Base T with auto-negotiation
RJ45 socket for CAT5 cabling
Dynamic (DHCP) or fixed
Loss of Ethernet synchronisation
Penta band LTE (4G)
800/900/1800 MHz
2100/2600 MHz
Dual band UMTS (3G)
900/2100 MHz
Dual band GSM (2G)
900/1800 MHz
SMA socket for antenna
Loss of registration with network
Note:
Cabling must not
exceed 3 meters
transmission paths
200
Fault reporting to the alarm panel .
If the dialler is unable to poll to the monitoring centre it reports this
to the alarm panel using a method dependent on the panel interface
mechanism: Dial capture: The line voltage is dropped to simulate
loss of a PSTN connection . Serial: Either regular polls to the interface
are ignored or an explicit message is sent to the panel, depending on
the serial protocol in use . Pin inputs: A relay output can be set open
to indicate fault .
Alarm protocols
SIA (level 1 to 3) reference SIA DC-03-1990 . 0 1(R2003 . 1 0),
Contact ID reference SIA DC-05-1999 . 0 9, Fast format (Scancom),
Robofon (Dial capture only), Telim (Dial capture only),
CESA (Dial capture only)
Tamper detection reporting to
Dial capture interface, Lid & back tamper, Serial Interface, Pin inputs
Monitoring Centre
Fault reporting to Monitoring Centre Transmission interface/path fault
The IRIS dialler constantly 'polls' the monitoring centre to report it is
operational and to report any interface or transmission faults it has
identified . If the dialler has more than one transmission path then all
paths are monitored and faults are reported by an operational path .
If all paths or the dialler fail this is identified by the loss of polls .
This allows the monitoring centre to monitor and calculate the
dialler's availability .
Substitution protection and
All transmissions are authenticated and encrypted using a unique
information security
256 bit security key . This key is automatically updated every day .
Relay outputs
Maximum operating voltage
24V DC
Maximum current rating
100mA DC
Power supply
Supply voltage
9V to 28V DC
Typical current
124mA @ 12V DC
Maximum current
1A @ 12V DC
Recommended external PSU
Note: For Radio Equipment Directive the power cable needs to be
no longer than 3 meters in length
Environmental
Operating temperature range
-10°C to 55°C
Operating humidity range
95% max ., non-condensing
Weights and dimensions
Physical dimensions
19 cm x 13 cm x 4 cm
PCB weight
550 grams
Fully packaged weight
750 grams
220
240
138mA @ 12V DC
140mA @ 12V DC
12V DC 1A 12 Watt
15