Data Signs PTL Compact 1 Panduan Pengoperasian dan Pemeliharaan - Halaman 7

Jelajahi secara online atau unduh pdf Panduan Pengoperasian dan Pemeliharaan untuk Peralatan Keselamatan Data Signs PTL Compact 1. Data Signs PTL Compact 1 19 halaman. Portable traffic lights

SHUTTLE MODE.
This can only be operated via the PTL Remote
Buttons used:
STOP
or GO
A demand for Green or Red signal phase on the Master or Slave is entered on the Remote
Control unit. For Shuttle Control, on start-up, both the Master and Slave will rest on
Red until a demand for Green is entered.
To enter a demand for either Red or Green, press the STOP or GO buttons on the Remote
Control. The DEMAND LED is activated indicating a demand for either the Master or Slave.
REMOTE
ACTIVE
Master / Slave Controller
For display use only
Shuttle Control example:
1. Slave unit is currently showing the Green signal.
2. GO button is pressed for the Master side.
3. If the Green time has expired, the Slave will cycle immediately to Yellow and then Red
signal. The Master DEMAND LED will flash until the Green is lit.
4. Press the GO button on the Slave side to change the Cycle back in the reverse as per above.
5. Note: You can hold BOTH Master and Slave on Red indefinitely by pressing either Red Light.
To return to Green simply select either Master or Slave Green again, the lights will
change when the minimum Red time has expired.
The REMOTE ACTIVE indicator lights up on both the Master and Slave controllers when the PTL
remote is connected.
REAR BEACON LAMP:
The Beacon Lamps mounted behind the Traffic Lights flash on each unit when the Red
Lights are ON.
on PTL Remote.
P T L O P E R A T I O N S M A N U A L
PTL Remote Screen
7