Assembling the circuit board (if not yet present on PREMIUM
machines)
Fig. 12: Connecting the throat plate slide interrogator (2)
(4)
(5) - Plug (of interrogator cable)
4. Position the socket (6) on the plastic housing (behind the cover on
5. Position the circuit board (4) over top.
6. Tighten the circuit board (4) through the plastic housing using the
12
④
⑤
- Circuit board
the side and next to the sewing motor).
screw (7) and the socket (6).
Connecting the throat plate slide interrogator
⑦
④
(6) - Socket (not visible)
(7) - Screw