DURKOPP ADLER 0867 590134 Petunjuk Manual - Halaman 11
Jelajahi secara online atau unduh pdf Petunjuk Manual untuk Aksesori Mesin Jahit DURKOPP ADLER 0867 590134. DURKOPP ADLER 0867 590134 16 halaman. Fitting remaining thread monitor for var. kits
Anbauanleitung des Restfadenwächters
Instructions for fitting remaining thread monitor
3
Mounting the thread monitor
3.1 Replacing the counter-knife and the bobbin case, screwing the light barrier
1
3.2 Mounting the control unit and the valve
5
Ausgabe/Edition:
10.2006
für div. Bausätze (siehe Pkt 1.1)
for var. kits (see section 1.1)
Caution Danger of injury !
Turn off the main switch.
Replace the thread monitor only with the sewing machine
switched off.
–
Replace the "old" bobbin case against the "new" one.
–
Screw on the pre-assembled support 2, using the screw 1
and/or 3.
Note:
In general, the front edge of the light barrier should be
parallel to the front edge of the support 2.
–
Connect the hose 4 for the blower.
2
–
Set the position of the light barrier in a way that its beam goes
through the slit of the bobbin case and can be reflected back
by the bobbin surface again.
–
Put the spacers 6 (4x) in the remaining thread monitor
support plate and put on the printed circuit board 5.
–
Connect the cable to the circuit board of the thread monitor
7 = valve circuit board
8 = for the light barrier of the left needle
9 = for the light barrier of the right needle
6 (4x)
Printed in Federal Republic of Germany
7
8
9
Teile-Nr./ Part-No.:
0791 867702
3
4
Blatt:
von
Sheet: 11