Duro Dyne PLSU3 Teori Operasi - Halaman 3
Jelajahi secara online atau unduh pdf Teori Operasi untuk Pemotong Duro Dyne PLSU3. Duro Dyne PLSU3 8 halaman.
Pic 2.1 HMI Power Cord Plug
Pic 2.2 HMI Network Cord Plug
Main Screen
When the 110V line cord is plugged in and one of the two main power push button
switches is pushed on, the touch-screen HMI will power up. While the HMI is powering up
DO NOT touch and hold the screen or else it will go into screen calibration mode. When
fully powered-up (<20 seconds) the HMI will automatically display the Main Screen
depicted in Pic.3.
Pic.3 Main Screen View
Cut Length: Enter the desired length of cut here by clicking the blue-outlined box, entering the value of
cut length, and pressing ENTER
Cut Count: Enter the desired quantity of cut-to-length pieces of insulation here by clicking the blue-
outlined box, entering the value of cut quantity, and pressing ENTER
Current Length: Shows the current length of how much material has past the encoder (for one cut
program)
Current Count: Shows the current count of how many pieces of have been cut during one cut program
Start: Begins the cutting program. Press this button after setting the cut count and cut length parameters
Reset: Resets the cut count to 0 and begins a new cutting program.
If the "current count" reads the same