Cavity Sliders Solic CS005 Panduan Pengoperasian - Halaman 16
Jelajahi secara online atau unduh pdf Panduan Pengoperasian untuk Sistem pembukaan pintu Cavity Sliders Solic CS005. Cavity Sliders Solic CS005 16 halaman. Automatic sliding door operator, motor - m005 (hypoid gear type)
9. DISPLAY INFORMATION FOR ERROR CODES/FAULTS
Fault list for microcomputer control box CS005
Error codes are displayed on the LED display as [Err xx]. The following two numbers
after the "Err" notation indicates the error that has occurred.
The following list of error codes can be indicated on the CS005 Microcontroller.
Error
Error/Fault
Code
Observed
Power
overvoltage
Power supply
low voltage
Motor sensor is
abnormal
Motor sensor U
is abnormal
Motor sensor V
is abnormal
Motor sensor W
is abnormal
EEPROM is
abnormal
IPM is abnormal IPM (power module)
Overload Fault
Error/Fault
Detection
Inside rectifier
voltage is over
DC255V for 10 sec.
or more
Inside rectifier
voltage is less than
DC50V for 3 sec. or
more
Either motor sensor
(U, V, W) is low or
high for 5 sec or
more
Motor sensor U has
not changed for
more than 5 sec.
during motor
operation
Motor sensor V has
not changed for
more than 5 sec.
during motor
operation
Motor sensor W has
not changed for
more than 5 sec.
during motor
operation
Communication to
internal memory
failed
abnormal condition
is more than 1 sec.
Door under
operation stops
more than 2 sec.
due to external
pressure
How to Clear
Likely Cause for Error/Fault
Error/Fault
•
Inside rectifier
voltage is under
DC225V for 1 sec.
•
or less
•
Inside rectifier
voltage is less
than DC50V for 1
sec. or more
•
Remove power.
Wait 5 seconds
•
and reconnect
power
•
•
Remove power.
Wait 5 seconds
•
and reconnect
•
power
•
Remove power.
Normally it does not occur
Wait 5 seconds
and reconnect
power
Remove power.
Wait 5 seconds
and reconnect
power
•
Remove power.
Wait 5 seconds
and reconnect
power
•
Remove power.
Wait 5 seconds
and reconnect
power
•
Run door though
standard
open/close cycle
High power supply voltage
(AC180V or over)
Excessive inertia due to
heavy door weight
Input AC power supply is
low voltage (AC36V or less)
Motor connector is missing
Wire for motor sensor is
broken
Motor is out of order
Motor connector is missing
Motor wire is broken
Motor is out of order
Motor shaft is locked
Memory in substrate is
abnormal
Memory in substrate is
abnormal
Due to obstacle and
wearing rollers, running
resistance is big
16