TECHNICAL FEATURES

ELECTRICAL FEATURES
Supply Voltage
Consumption
Limited Current Consumption
CBX + reading device consumption
(see related manual)
USER INTERFACE
LED Indicators
PHYSICAL FEATURES
Mechanical Dimensions
Weight
ENVIRONMENTAL FEATURES
Operating Temperature
Storage Temperature
Humidity max.
Vibration Resistance
EN 60068-2-6
2 hours on each axis
Shock Resistance
EN 60068-2-27
Protection Class
EN 60529
The features given are typical at a 25 °C ambient temperature (if not otherwise indicated).
*
for further details about minimum/maximum supply voltage refer to the manual of the connected reading
device, since the minimum supply voltage required may be >10.
** when compression connectors and reading device are correctly connected.
If Host Interface (Fieldbus) Modules are used, only correctly installed IP65 models guarantee IP protection.
Protection is not guaranteed when Standard Fieldbus Modules are mounted.
COMPLIANCE
POWER SUPPLY
This product is intended to be installed by Qualified Personnel only.
This device is intended to be supplied by a UL Listed NEC Class 2 power source.
CE COMPLIANCE
Warning: This is a Class A product. In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
CBX500 INSTALLATION MANUAL
10 to 30 Vdc*
0.8 – 0.5 A
2.5 A
Power On/Polarity Error (blue/red)
Trigger (yellow)
IN2 (green)
OUT1 (yellow)
OUT2 (green)
193 x 180 x 71 mm
(7.6 x 7.1 x 2.8 in.)
about 780 g. (27.5 oz.)
0° to 50 °C (+32° to 122 °F)
-20° to 70 °C (-4° to 158 °F)
90% non condensing
14 mm @ 2 to 10 Hz
1.5 mm @ 13 to 55 Hz
2 g @ 70 to 200 Hz
30 g; 11 ms;
3 shocks on each axis
IP65 **