Connection diagrams
Drive and MF outputs WS1 Style (60180-60189):
max. 400 W per motor output,
total max. 1.5 kW for all motor outputs
Drive and MF outputs WS1 Style-PF (60194):
per motor output max. 5 A / 230 V
Mounting of WS1 Style
Inputs WS1:
Connection examples for multifunctional outputs
Connecting 230 V consumers to MF outputs
multifunctional outputs 1-4 WS1000 Color/Style
multifunctional outputs 1-2 WS1 Color/Style
MF output 1
neutral conductor
Mounting of WS1 Style • Version: 30.06.2020 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de • Technical Service: +49 (0) 7033 / 30945-250
MF output 2
MF output 3
MF output 4
Connecting low-voltage consumers and potential-free contacts to MF
outputs
multifunctional outputs 1-4 WS1000 Color/Style
multifunctional outputs 1-2 WS1 Color/Style
MF output 1
MF output 2
e.g. 24 V (ext.power supply)
Technical specifications Control Unit WS1 Style
Housing
Glass, plastic material
Colours
• White/grey
• Dark grey/black
Mounting
Flush/cavity wall
Dimensions
Display front approx. 181 × 131 (W × H, mm),
mounting depth approx. 8 mm,
concealed box approx. 172 × 122 × 81 (W × H
× D, mm)
Ambient temperature
Operation 0...+55°C, Storage -30...+70°C
Ambient humidity
5...95% RH, avoid bedewing
Operating voltage
230 V AC, 50 Hz
Power consumption
Stand-by max. 11 W
Loading capacity
per drive output max. 400 W,
drive outputs
total max. 1.5 kW
Frequency
868.2 MHz
wireless channels
Protection category
IP 20
Measurement range
0...+55°C
temperature
Resolution (tempera-
0.1°C
ture)
Measurement range
5...95% RH
humidity
Resolution (humidity)
0.1% RH
The product conforms with the provisions of EU directives.
2
MF output 3
MF output 4
signal contact for e.g.
rain / wind / frost /
smoke detector / alarm
thermostat
replacement