Elsner 70140 Manual

Jelajahi secara online atau unduh pdf Manual untuk Catu Daya Elsner 70140. Elsner 70140 2 halaman. Power supply system

EN
KNX PS640 Power Supply System
Manual
Item number 70140
1.
Installation and Commissioning
Installation, testing, operational start-up and troubleshooting should
only be performed by an authorised electrician.
DANGER!
Risk to life from live voltage (mains voltage)!
• Inspect the device for damage before installation. Only put undamaged
devices into operation.
• Comply with the locally applicable directives, regulations and provisions for
electrical installation.
• Immediately take the device or system out of service and secure it against
unintentional switch-on if risk-free operation is no longer guaranteed.
Use the device exclusively for building automation and observe the operating inst-
ructions. Improper use, modifications to the device or failure to observe the opera-
ting instructions will invalidate any warranty or guarantee claims.
Operate the device only as a fixed-site installation, i.e. only in assembled condition
and after conclusion of all installation and operational start-up tasks, and only in the
surroundings designated for it.
Elsner Elektronik is not liable for any changes in norms and standards which may
occur after publication of these operating instructions.
For information on installation, disposal, scope of delivery and
technical data, please refer to the installation instructions.
2.
Description
The Power Supply System KNX PS640 delivers a 29 V bus voltage for one line
of the KNX building bus system and the supply voltage for 24 V DC devices. Special
operating conditions such as short circuit, overvoltage, overload or excess tempe-
rature are recorded and may be read off on the display. The present power dischar-
ge is displayed as well. A reset of the line is possible via the keypad.
Functions:
Delivers a 29 V KNX bus voltage (reduced), output current max. 640 mA,
short-circuit proof
Delivers 24 V DC (not reduced), output current max. 150 mA
Reset of a line directly on the device
Record of operating hours, overload, external overvoltage, internal
overvoltage, short circuit and excess temperature
Display of operating data bus voltage, bus current and temperature of the
device
The display may be shown in German, English, Spanish or Dutch
2.1. Starting Position
elsner elektronik
KNX Power Supply
Normal Operation
Diagnostics >
The following may be read off and set on the display of the power supply system
KNX PS640:
Reset of a line
Recall of the data memory with operating hours, overcharge, external
electrical surge, internal electrical surge, short circuit and excess temperature
Recall of the operating data bus voltage, bus current and temperature
Language of display
The display is dimmed after 60 seconds if during this period no key is pressed.
2.2. Key functions in display menu
Confirms the selection, moves to the next
step.
One step back.
Changes a setting (selects a setting or changes
a value). The cursor (the blinking rectangle)
indicates the selected menu item.
ok
Confirms the settings and returns to the device
main menu.
Power Supply System KNX PS640 • Version: 28.11.2023 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de • Technical Service: +49 (0) 7033 / 30945-250
Power Supply System KNX PS640
2.3. Line reset
Standard screen:
elsner elektronik
KNX Power Supply
Normal Operation
Diagnostics >
Press key
Line Reset
Data Memory
Operating Data >
Language
Press key
Reset: Yes
Reset not active!
Move the cursor (flashing rectangle at right edge) to the desired setting with the
keys
Yes
No
30 seconds
With key
2.4. Data memory
Standard screen:
elsner elektronik
KNX Power Supply
Normal Operation
Diagnostics >
Press key
Line Reset
Data Memory
Operating Data >
Language
Move the cursor (flashing rectangle at right edge) to the „Data memory" menu with
the keys
Hours ofOperation > ™
Overload
Ext. Overvoltage
Int. Overvoltage
Move the cursor to the desired menu with the up and down keys and press key
2.4.1. Operating hours
Run time: 0 years
< = Back
2.4.2. Overload
Run time: 0 years
< = Back
2.4.3. External Overvoltage
External Overvoltage
was detected
0 times.
< = Back
2.4.4. Internal Overvoltage
Internal Overvoltage
was detected
0 times.
< = Back
2.4.5. Short Circuit
A short at the bus was
detected
0 times.
< = Back
2.4.6. Excess Temperature
Excess Temperature on
the board
was detected
0 times!
once.
> ™
>
>
once more in order to get into the sector „Line reset".
No
30 seconds
or
and confirm with key
Reset is activated. The line is switched to neutral and
shorted. The basic setting displays: „Reset is active!"
Reset not activated. The power supply system works in
normal operation.
A reset of 30 seconds is started. Afterwards, the line is
supplied with voltage as usual. During the reset state,
which lasts 30 seconds, the basic setting displays:
„Reset active: XX sec" (countdown).
, you return to the previous menu level.
once.
>
> ™
>
and
and confirm with key
Short circuit
>
Excess Temperat.
>
>
The operating hours of the power supply system are
displayed in years, days and hours.
0 day 0 hrs.
With key
The number of overload incidents and the total time
in days, hours and minutes are displayed.
0 day 0 hrs.
With key
The number of external overvoltage incidents is di-
splayed.
With key
The number of internal overvoltage incidents is di-
splayed.
With key
The number of short circuit incidents at the bus is di-
splayed.
With key
The number of excess temperature incidents on the
circuit board of the device is displayed.
With key
.
ok
.
>
>
you return to the previous menu level.
you return to the previous menu level.
you return to the previous menu level.
you return to the previous menu level.
you return to the previous menu level.
you return to the previous menu level.
1
.