elsner elektronik 60126 Instruksi Singkat

Jelajahi secara online atau unduh pdf Instruksi Singkat untuk Unit Kontrol elsner elektronik 60126. elsner elektronik 60126 2 halaman.

elsner elektronik 60126 Instruksi Singkat
EN
Brief Instruction
Mounting of WS1000 Color
Item numbers 60121-60128 (WS1000 Color)
The manual with additional information about commissioning,
functions and use of the controls WS1000 Color can be down-
loaded from www.elsner-elektronik.de in the menu area "Ser-
vice/Downloads".
Warning, mains voltage! National legal regulations are to be
observed. Installation, inspection, commissioning and
troubleshooting of the device must only be carried out by a
competent electrician.
Notes on wireless equipment
When planning facilities with devices that communicate via radio, adequate radio
reception must be guaranteed. The range will be limited by legal regulation and
structural circumstances. Avoid sources of interference and obstacles between re-
ceiver and transmitter, that could disturb the wireless communication. Those
would be for example:
Walls and ceilings (especially concrete and solar protection glazing).
Metal surfaces next to the wireless participants (e. g. aluminium
construction of a conservatory).
Other wireless devices and powerful local transmitters (e.g. wireless
headphones), which transmit on the same frequency. Please maintain a
minimum distance of 30 cm between wireless transmitters for that reason.
Preparing the installation location
The device must only be installed and used in dry, interior
spaces. Avoid condensation.
Cut-out dimensions for concealed box (approx.): W=229 mm | H=163 mm | D=62
mm:
An external antenna can be connected in order to improve wireless communicati-
ons. During installation, a conduit 50 cm in length should be placed beneath the
recessed housing, in which the external antenna can be mounted (antenna dimen-
sions approx. 565 x 8 x 5, L × W × H in mm):
Conduit angled diagonally dow-
Conduit angled vertically downwards (only
nwards (for cable access from
for cable access from above!)
above or below)
concealed
concealed
box
box
cable
45°
M16 conduit, 50 cm in length
Preparing for installation
To take off the front plate, remove the
screws beneath the lid.
The lid cover is only attached by a hinge. Take care not to lose it.
Wall-fitting
Cavity wall fitting
Assembling the control unit with concealed box
During electrical installation, please introduce all connection cables into the con-
cealed box through the lower or upper side wall. In the process, keep the individual
connection wires short to prevent long reserve loops.
cable
M16 conduit,
50 cm in length
After connecting the cables screw the lower section of the housing (with the moun-
ting plate) onto the concealed box. Connect the flat ribbon cable to the display.
Put the lid cover on the upper section of the housing (frame with display). Put the
upper section of the housing onto the lower section of the housing from above and
move it downwards until the bottom edges are aligned. Screw on the upper secti-
on.
Mounting of WS1000 Color • Version: 27.05.2021 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de • Technical Service: +49 (0) 7033 / 30945-250
Mounting of WS1000 Color
Push the upper section of the housing
(frame with display) up a little and lift it
off.
Caution: The display is connected
with a flat-ribbon cable to the circuit
board in the concealed box. Loosen
the plug so that the upper section
can be removed.
The lower section of the housing together
with the wall-mounting plate is attached
to the concealed box with 3 screws: Loo-
sen the screws and take off the lower part.
Remove the circuit board from the con-
cealed box to be installed a keep it in a
place where it is protected from dirt. It
may never be exposed to dust or mo-
isture!
For fitting, screw the cover (board) on to
the concealed box with the enclosed
screws.
Clamp the concealed box to the wall with
the four enclosed screws.
Upon delivery, the pouch containing the
or
assembly screws can be found in the con-
trol unit's flush-mounted casing.
Structure of the connector board WS1000 Color
1
2
5
7
8
9
28
3
4
6
12
13
14
18
19
24
22
23
21
20
1 Multifunctional output 1
20 Wall button 9 (terminals 1-3)
(potential-free)
Wall button 10 (terminals 4-6),
2 Multifunctional output 2 (pot.-free)
21*Multifunctional input 1
3 Multifunctional output 3 (pot.-free)
(terminals 1-3)
4 Multifunctional output 4 (pot.-free)
Multifunctional input 2
5 Outer conductor L1
(terminals 4-6)
6 Outer conductor L1
22 Weather station (terminals 1-2)
7 Drive group 1
Wire assignment: red = 1, black = 2,
8 Drive group 2
yellow and white = not connected
9 Drive group 3
23*Multifunctional input 3
10 Drive group 4
(terminals 3-5)
11 Drive group 5
Multifunctional input 4
12 Drive group 6
(terminals 6-8)
13 Drive group 7
24 Connector for flat-ribbon cable to
14 Drive group 8
front board
15 Drive group 9
25 Microfuse T6.3 A (Drive 1-5)
16 Drive group 10
26 Microfuse T6.3 A (Drive 6-10)
17 Mains connection L/N/PE 230 V/50
27 Microfuse T630 mA
Hz
28 Slot KNX interface
18 Wall button 1 (terminals 1-3)
Wall button 2 (terminals 4-6)
* Supply voltage indoor sensor possi-
Wall button 3 (terminals 7-9)
ble via MF inputs
Wall button 4 (terminals 10-12)
(No. 21, terminals 1(+), 2(-) | 4(+),
19 Wall button 5 (terminals 1-3)
5(-) and No. 23, term. 3(+), 4(-) | 6(+),
Wall button 6 (terminals 4-6)
7(-)), max. 400 mA altogether.
Wall button 7 (terminals 7-9)
Wall button 8 (terminals 10-12),
Connection diagram
Drive and MF outputs WS1000 Color:
per drive output max. 400 W,
total max. 1.5 kW
1
10
11
25
15
16
17
26
27