Datalogic S5N-MH Series Buku Petunjuk
Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Pembaca kode batang Datalogic S5N-MH Series. Datalogic S5N-MH Series 5 halaman.
This product is covered by one or m ore of the following patents.
European Patent 851,211 B1; 1,111,690 B1; 1,148,346 B1; 1,209,487 B1.
Italian Patent IT 1,321,772.
S5N-PH/MH SERIES
INSTRUCTION MANUAL
CLASS 1 IEC 60825-1 (2014)
LASER PRODUCT
IEC 60825-1 "Caution – use of controls or adjustments or performance of
procedures other than those specified herein may result in hazardous
radiation exposure"
CONTROLS
OUTPUT LED (S5N-PH/MH...B01/C01/F01)
The yellow LED ON indicates that the N.O. (normally open) output status
is closed.
POW ER ON LED
The green LED indicates that the sensor is operating.
TRIMMER (S5N-PH/MH...B01/C01/F01)
The trimmer can be used to adjust sensitivity; the operating distance
increases turning the trimmer clockwise.
W ARNING: The trim m er rotation is lim ited to 270° by a m echanical stop.
Do not apply excessive torque when adjusting (m ax 40 Nm m ).
INSTALLATION
S5N-PH: The sensor can be fixed by means of the M18x1 threaded body
through a 18 mm hole, using the specific washer and the two CH.24
nuts enclosed (1.5 Nm maximum tightening torque).
Amongst the various possible solutions, we suggest to choose the
combination that offers the best visibility of the signalling LEDs and the
easiest access to the trimmer.
22 mm nuts, h=8 mm, (2 Nm maximum tightening torque) are available to
guarantee an improved torque.
S5N-MH: The sensor can be fixed by means of the M18x1 threaded body
through a 18 mm hole, using the two CH.24 nuts enclosed (22 Nm
maximum tightening torque).
Various orientable fixing brackets for both plastic and metallic versions
are available to ease sensor positioning (please refer to the accessories
listed in the general catalogue).
The operating distance is measured from the front surface of the sensor
lens.
The connections are compliant to the EN 60947-5-2 standard.
S5N-PH/MH...B01/C01/F01
BROWN
1
BROWN
+
10 ... 30 Vdc
WHITE
2
WHITE
N.C. OUTPUT
4
BLACK
BLACK
N.O. OUTPUT
BLUE
3
BLUE
0 V
S50-PH VERSION
S5N-PH VERSION
with
trimmer
L
L
79
14.5
X
43
12
2
1.5
X1
46
3.5
4
4
25
CABLE VERS.
X
14.5
10
TRIMMER
N°.2 Ø3.8
POWER ON LED
X1
OUTPUT LED
15
OUTPUT LED
TECHNICAL DATA
S5N-PH PLASTIC VERSIONS
Power supply:
Ripple:
Current consumption
(output current excluded):
Outputs:
Output current:
Output saturation voltage:
Response time:
Switching frequency:
Indicators:
Setting:
Operating mode:
DARK mode on N.O. output / LIGHT mode on N.C. output (mod.B01/F01)
Operating temperature:
Storage temperature:
Insulating strength:
Insulating resistance:
Operating distance (typical values):
Emission type:
Max. power 1 mW; Pulse = 5 s; = 645...660 nm; Frequency 25 kHz
Ambient light rejection:
0.5 mm amplitude, 10 ... 55 Hz frequency, for every axis (EN60068-2-6)
Vibrations:
Shock resistance:
Housing material:
Lens material:
Mechanical protection:
Connections:
Weight:
75 g. max. cable vers. /25 g. max. conn. vers.
CONNECTIONS
S5N-PH/MH...G00
M12 CONNECTOR
1
+
10 ... 30 Vdc
2
2
TEST +
4
3
NOT USED
3
0 V
DIMENSIONS
M O D E L S
S50-MH VERSION
S5N-MH VERSION
without
trimmer
L
69
14.5
42
12
4
4
36
14.5
X
10
10
TRIMMER
POWER ON LED
POWER ON LED
OUTPUT LED
61
mm
S5N-MH METAL VERSIONS
10 ... 30 Vdc limit values
2 Vpp max.
35 mA max. (mod.B01/C01/F01)
30 mA max (mod.G00)
N.O. and N.C.; PNP or NPN (short-circuit protection)
100 mA max.
2 V max.
333 s
1.5 kHz
OUT PUT LED (YELLOW) (mod.B01/C01/F01)
POWER ON LED (GREEN)
sensitivity trimmer (mod.B01/C01/F01)
LIGHT mode on N.O. output / DARK mode on N.C. output (mod.C01)
-10 ... 50 °C
-25 ... 70 °C
500 Vac 1 min., between electronics and housing
>20 M 500 Vdc, between electronics and housing
B01: 0.1...9 m on R2 reflector
C01: 0...25 cm
F01/G00: 0...50 m
RED LASER: Class 1 IEC 60825-1 (2014) (mod.B01/C01/G00)
Class 1 CDRH 21 CFR PART 1040.10 (mod.B01/C01/G00)
According to EN 60947-5-2
11 ms (30 G) 6 shock for every axis (EN60068-2-27)
PBT
Nickel-plated brass
PMMA
IP67 Metal versions type 1 enclosure
2 m cable 4 mm / M12 - 4 pole connector
110 g. max. cable vers. /60 g. max. conn. vers.
SETTING
Setting of S5N-PH/MH...B01
Position the sensor and reflector on opposite sides.
Turn the sensitivity trimmer to the maximum position.
Moving the sensor both vertically and horizontally, determine the power
ON and OFF points of the OUTPUT LED and then mount the sensor in
the middle of the points defined.
1
If necessary reduce sensitivity in order to detect very small targets.
In order to improve alignment, repeat the given procedure whilst
progressively reducing the sensitivity.
4
Setting of S5N-PH/MH...F01/G00
Position the sensor and reflector on opposite sides.
Turn the sensitivity trimmer to maximum: moving the sensor both
vertically and horizontally, determine the power ON and OFF points of the
OUTPUT LED and then mount the sensor in the middle of the points
defined.
If necessary, reduce sensitivity using the trimmer, in order to detect very
M O D E L S
with
without
small targets. In order to improve alignment, repeat the procedure
trimmer
trimmer
L
79
69
detailed above whilst progressively reducing the sensitivity.
X
43
38
Setting of S5N-PH/MH...C01
Turn the sensitivity trimmer to minimum: the OUTPUT
LED is OFF.
Position the target to detect in front of the sensor.
Turn the sensitivity trimmer clockwise until the
OUTPUT LED turns ON (Target detected state, pos.A).
CABLE VERS.
Remove the target, the OUTPUT LED turns OFF.
10
Turn the sensitivity trimmer clockwise until the OUTPUT LED turns ON
(Background detected state, pos.B).
The trimmer reaches maximum if the background is not detected.
Turn the trimmer to the intermediate position C, between the two
POWER ON LED
positions A and B.
OUTPUT LED
TEST FUNCTION (S5N-PH/MH...G00)
The TEST+ input can be used to deactivate the emitter and verify that the
system is operating correctly.
The receiver output should switch when the test is activated while the
beam is uninterrupted.
The input activating voltage range is 10...30 Vdc.
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com: Contact Us, Terms and
Conditions, Support.
The warranty period for this product is 36 months. See General Terms
and Conditions of Sales for further details.
For information about the disposal of Waste Electrical
and Electronic Equipment (WEEE), please refer to the
website at www.datalogic.com.
© 2018 - 2019 Datalogic S.p.A. and/or its affiliates ALL RIGHTS
RESERVED. Without limiting the rights under copyright, no part of
this documentation may be reproduced, stored in or introduced into a
retrieval system, or transmitted in any form or by any means, or for any
purpose, without the express written permission of Datalogic S.p.A.
and/or its affiliates. Datalogic and the Datalogic logo are registered
trademarks of Datalogic S.p.A. in many countries, including the U.S.A.
and the E.U. All other trademarks and brands are property of their
respective owners. Datalogic reserves the right to make modifications
and improvements without prior notification.
826000422 Rev.C
A
C
B
MAX
MIN