2.8. Door Station DIP setting
Total 6 bits in the DIP switches can be configured. The switches can be modified either before or after installation.
Bit definition
Bit-1 and bit-2
Door Station ID
setting
Bit-3
User ID select
Bit-4
Button line select
Bit-5
Unlocking time quick
select
Bit-6
Function reserved
2.9. Standard Electronic Lock Connection
This example is a standard electronic lock wiring, by connecting the lock directly to the door station. note that the lock used here is
a 12Vdc 500mA power-to-unlock type. (other locks can be supported, please refer to DT technical manual for Lock connection detail
information-)
ON
1
2
3
4
5
6
Bit state
Default setting, ID = 0, set to the first Door Station.
1 2
3 4 5 6
ON
ID = 1, set to the second Door Station.
1 2
3 4 5 6
ON
ID = 2, set to the third Door Station.
1 2
3 4 5 6
ON
ID = 3, set to the fourth Door Station.
1 2
3 4 5 6
ON
Default setting for using a double line button Door Station.
1 2
3
4 5 6
ON
when using a single line button Door Station.
1 2
3
4 5 6
ON
Default setting for using the default codes of the button.
1 2 3
4
5 6
ON
using the progremmed codes of the button.
1 2 3
4
5 6
ON
Default setting, unlocking time = 1 second.
1 2 3 4
5
6
ON
Unlocking time = 5 seconds.(can be changed by software)
1 2 3 4
5
6
ON
Working state.
1 2 3 4 5
6
ON
Function reserved.
1 2 3 4 5
6
ON
Electronic Lock
-
+
Exit Button
- 11 -
ON(1)
OFF(0)
=
=
O N
O N

Function Descriptions

+12V
T/R -
LK - (GND)
T/R+
LK+(COM)
N.O.
EB+
EB -
DMR11

Connection Board

PA
1
L1
L2
2
3
PB
Connect to DPS or DPS-4