Datalogic TC1100-1100 Panduan Referensi Cepat
Jelajahi secara online atau unduh pdf Panduan Referensi Cepat untuk Pemindai Datalogic TC1100-1100. Datalogic TC1100-1100 2 halaman. Ccd scanner
CODE SELECTION
EAN/UPC disable
AA0
EAN 8/EAN 13/UPC A/UPC E enable
AA1
AA5
AA8
EAN 8/EAN 13 enable
AA3
AAK
AAL
AA6
UPC A/UPC E enable
AA4
AAM
AAN
AA7
EAN 8 enable
AAG0
AAG1
EAN 13 enable
AAH0
AAH1
UPC A enable
AAI0
AAI1
UPC E enable
AAJ0
AAJ1
Code 39 disable
AB0
Code 39 Standard enable
AB11xxyy
AB12xxyy
AB13xxyy
Code 39Full ASCII enable
AB21xxyy
AB22xxyy
Code 2/5 family disable
AC0
Interleaved 2/5 enable
AC11xxyy
AC12xxyy
AC13xxyy
Normal 2/5 5 bars enable
AC21xxyy
AC22xxyy
AC23xxyy
Industrial 2/5 (IATA) enable
AC31xxyy
AC32xxyy
AC33xxyy
Matrix 2/5 3 bars enable
AC41xxyy
AC42xxyy
AC43xxyy
Codabar family disable
AD0
Codabar standard enable
AD111xxyy
AD112xxyy
AD121xxyy
AD122xxyy
AD212xxyy
Code 128 family disable
AI0
Code 128 enable
AI11 xxyy
EAN 128 enable
AI21 xxyy
Code Length
AILxxyy
Code 93 family disable
AK0
Code 93 enable
AK1 xxyy
PDF417 disable
AR0
PDF417 enable
AR1
Pharmacode disable
AQ0
Pharmacode enable
AQ1xxyy
AQ2xxyy
Overflow ratio
AQAzz
xxyy = ASCII numbers that define:
xx = min. acceptable code length
yy = max. acceptable code length
The minimum code length must always be less than or equal to the maximum.
For more detailed information on the TC1100 programmability and complete parameter list, please refer to the
TC1100 Reference Manual.
N2468
821000676 (Rev. H)
without ADD ON
with ADD ON
with and without ADD ON
without ADD ON
with ADD ON 2 ONLY
with ADD ON 5 ONLY
with ADD ON 2 AND 5
without ADD ON
with ADD ON 2 ONLY
with ADD ON 5 ONLY
with ADD ON 2 AND 5
check digit transmission disable
check digit transmission enable
check digit transmission disable
check digit transmission enable
check digit transmission disable
check digit transmission enable
check digit transmission disable
check digit transmission enable
no check digit control
check digit control and transmission
check digit control without transmission
no check digit control
check digit control and transmission
no check digit control
check digit control and transmission
check digit control without transmission
no check digit control
check digit control and transmission
check digit control without transmission
no check digit control
check digit control and transmission
check digit control without transmission
no check digit control
check digit control and transmission
check digit control without transmission
no start/stop character equality control - nor transmission
no start/stop character equality control but transmission
start/stop character equality control but no transmission
start/stop character equality control and transmission
ABC Codabar no start/stop character equality control but transmission
control without transmission of check digit
control without transmission of check digit
control without transmission of check digit
forward code tx direction
reverse code tx direction
zz = overflow ratio value
TC1100
CCD Scanner
Quick Reference Guide
The TC1100 is a linear CCD Scanner for OEM applications. It is available in two different versions:
Model
Description
TC1100-1100
CCD scanner for linear codes
TC1100-1200
CCD scanner for linear and PDF417
Technical Specifications
Power supply
5 Vdc ± 5%
Consumption
1.5 W
Interfaces
RS232, WEDGE, PEN Emulation
Max Scans/sec
270
Max resolution
0,076mm (3mils)
EAN/UPC, Code 39, 2/5 family, Codabar, Code 128, EAN 128, ISBT 128, Code 93,
Readable codes:
pharmaceutical codes, Delta IBM, Code 16K, Code 49, (Telepen, MSI/Plessey, Pharmacode
only TC1100-1100), (Codablock-A, Codablock-F Std, Codablock-F EAN, PDF417 only
TC1100-1200)
Default Configuration
Power Save
270 scans/sec, sleep disabled, standby disabled
Reading Parameters
On-Line
Code Selection
• Interleaved 2 of 5: Check Digit transmitted, length: min 4, max 99
• Code EAN8, EAN13, UPCA, UPCB: without ADD ON, Check Digit transmitted, no conversions
Enabled codes
• Code 39: length: min 1, max 99
• Code 128: Check Digit not transmitted, length: min 1, max 99
• PDF417
(Only TC1100-1200)
Data Format
Code ID disabled, Header = <STX>, Terminator = <CR> <LF>, no Field Adjustment, Code
length TX disabled, character replacement disabled, No Read Character = <CAN>
Decoding Parameters
Ink spread enabled, overflow control enabled, interdigit control enabled, Puzzle Solver™
disabled, decoding safety = 1 read
Enabled interface
RS232, 9600, N, 8, 1, no handshaking, ACK/NAK disabled, RX timeout 100 ms, FIFO
enabled, inter-character delay disabled
Reading Diagrams
mm
0
20
40
60
80
100 120
140
160 180
200 220
240 260
280 300
320
160
140
120
100
0.20 mm
80
60
40
20
0
-20
-40
-60
-80
-100
-120
0.13 mm
0.20 mm
0.30 mm
0.50 mm
-140
(5 mils)
(8 mils)
(12 mils)
(20 mils)
-160
Reading Diagram TC1100-1100 (code 39)
Order Number
939501020
939501030
mm
0
10
20
30
40
50
60
70
80
90 100 110 120 130 140 150 160 170 180
90
80
70
60
50
0.17 mm
40
(6.6 mils)
30
20
10
0
10
-
0.25 mm
-20
(10 mils)
-30
-40
-50
-60
0.38 mm
-70
(15 mils)
-80
-90
Reading Diagram TC1100-1200 (PDF417)