PHYSICAL LAYER

Description
IO-Link Revision
SIO Modus
Min Cycle Time
Transmission Rate
Process Data Length
M-Sequence Capability

SERVICE DATA

The following ISDUs will not be saved via Data Storage: Device Access Locks (index 0xC), Teach-in Channel (index 0x3A), Emitter Status (index 0x51) Keylock (index 0x58)
System Parameters
Parameter
Subindex
Index (dec)
Lenght
Value/Range
Object Name
(offset)
Device Access
Bit 0: Parameter (write) access (0 = unlocked, 1 = locked)
0x000C (12)
2 octets
Locks
Bit 1: Data Storage (0 = unlocked, 1 = locked)
2 octets
0x0001
2 octets
0x8000
Profile
2 octets
0x8001
0x000D (13)
Characteristics
2 octets
0x8003
2 octets
0x8004
2 octets
0x8007
3 octets
0x01.0x01.0x00
3 octets
0x01.0x01.0x01
PDInput
0x000E (14)
3 octets
0x01.0x01.0x02
Descriptor
3 octets
0x01.0x01.0x03
3 octets
0x01.0x01.0x04
Identification Parameters
Index
Parameter Object
Subindex
Lenght
(dec)
Name
(offset)
0x0010 (16)
Vendor Name
9 octets
0x0011 (17)
Vendor Text
19 octets
0x0012 (18)
Product Name
14 octets
0x0013 (19)
Product ID
5 octets
0x0014 (20)
Product Text
15 ÷ 22 octets
0x0015 (21)
Serial Number
9 octets
0x0016 (22)
Hardware Revision
5 octets
0x0017 (23)
Firmware Revision
5 octets
0x0018 (24)
Application Specific Tag
32 octets
0x0019 (25)
Function Tag
32 octets
0x001A (26)
Location Tag
32 octets
S8
parameters
FEATURES
Description
1.1
Block Parameter
YES
Data Storage
2.3 ms
Supported Access Locks
38.4 kbit/s (COM2)
PDInput: 4 Bit / 5 Bit (B53)
PDOutput: Not used
PREOPERATE: TYPE_0
OPERATE: TYPE_2_1
Profile Characteristic
ISDU: supported
Description
Standardized Device locking functions:
Bit 0: Parameter (write) access
Bit 1: Data Storage
Bit 2: Local parameterization (Not used)
Bit 3: Local user interface (Not used)
Bit 4-15: Reserved
Smart Sensor Profile
Device Identification
Switching Signal Channel (SSC)
Device Diagnosis
Teach Channel
Teach-in single value
SSC1 (OUT0)
SSC2 (OUT1)
TEACH STATUS FLAG
Switch Counter
Alarm (B53)
Value/Range
Description
DATALOGIC
Informative
Empower your vision
Detailed product name
See "Device variant collection"
Product identification
See "Device variant collection"
See "Device variant collection"
Unique serial number
RevAD
1.0.0
*** (default)
Tag application defined by user
*** (default)
Additional tag for device function identification
*** (default)
Additional tag for device function identification
YES
YES
Parameter (write) access
Data Storage
Device Profile: Smart Sensor
Function Class: Device Identification
Function Class: Switching Signal Channel
Function Class: Device Diagnosis
Function Class: Teach Channel
Function Class: Teach-in Single Value
Data Type
RecordT
ArrayT of
UIntegerT16
ArrayT of
OctetStringT3
Data Type
Access*
Remark
StringT
RO
StringT
RO
StringT
RO
StringT
RO
StringT
RO
StringT
RO
StringT
RO
StringT
RO
StringT
R/W
Saved in non-volatile memory
StringT
R/W
Saved in non-volatile memory
StringT
R/W
Saved in non-volatile memory
Access*
R/W
RO
RO
*RO = read only, WO = write only, R/W = read/write