DUSTLESS BLASTING DB350 Mobile XS Panduan Cepat - Halaman 3
Jelajahi secara online atau unduh pdf Panduan Cepat untuk Peralatan Industri DUSTLESS BLASTING DB350 Mobile XS. DUSTLESS BLASTING DB350 Mobile XS 6 halaman. Flex cart start up & shut down
5. Connect the blast pot to the power supply as shown in the Figure below.
Power supply
cord (connect
this cord)
Redhead electric
deadman power
supply (do not
connect this cord)
6. Press the button on the back of the air cooling and drying radiator to turn the fan on. If the power is
connected properly, the fan will turn on and the button will illuminate red.
7. Fill the blast pot according to the pot user manual instructions.
Caution:
The blast pot should remain depressurized during the fill process. The air-inlet shutoff valve on the
blast pot should be closed and the blow down valve should be open.
Note: Adjust the outlet pipe according to the blast pot user manual section Adjusting Abrasive Flow
Rate. A good measurement to start blasting with the Flex Cart setup is 3/16" of an inch. Each quarter
turn of the abrasive valve raises the outlet pipe 1/16" of an inch.
Outlet pipe
Connect the power supply cord to the cord on the air cooling
and drying system.
3